Commissioning the heat pump
Wait approximately 5 minutes after switching off the compressor before activating
rapid restart of the heat pump, to allow the cooling circuit time to equalise pressure.
In the menu 5.7 you set whether the heat pump, additional heat and hot water
charging should be controlled externally. When the external input on the control
unit is short circuited you can make one of the following choices:
0 : No effect (factory setting).
1 : HP, additional heat and hot water stop.
2 : HP no effect, additional heat and hot water stop.
3 : HP and hot water no effect, additional heat stops.
4 : HP and additional heat no effect, hot water stops.
Select the language that you would like for the menu texts.
The heat pump is set for continuous operation of the heat carrier pump on delivery.
In systems with a bypass, you can choose whether the heat carrier pump starts and
stops with the compressor.
Choose whether the heat transfer fl uid pump shall run continuously, for example,
when using *natural cooling. The heat transfer fl uid pump should in normal mode
always start and stop with the compressor.
Select this menu to see the version number of the control unit.
Confi rm the extra sensors T3 (GT3), T4 (GT4) and T5 (GT5) that are connected
externally. On confi rmation, the control unit stores information about the sensors to
be used.
Timer readings
There are a number of different menu displays to help you check the status of the
heat pump. The heat pump status is shown by the timer readings in menu 6.
Read the additional heat timer
The function shows the amount of time remaining before the additional heat is
activated. If there is no countdown then there is no need of additional heat.
Read the start delay
* Natural cooling: In winter the heat pump takes heat from the bore hole in the rock and converts this to
heat in the house. In the summer the cold in the same bore hole is used to give pleasant air conditioning.
If any of the alternatives to the left are
selected it is not possible to utilise any
of the functions in the menu Remote
control temperature (menu 1.13). See
Extra functions in the user section.
68
Commiss./Service
Select external
controls
5.7
Return
Select
Note
Commiss./Service
Selection of
language menu
5.8
Return
Select
Commiss./Service
Select operation
alt. for P2
5.10
Return
Select
Commiss./Service
Select operation
alt. for P3
5.11
Return
Select
Commiss./Service
Display software
version number
5.12
Return
Select
Commiss./Service
Connected extra
sensor in op
5.13
Return
Select
Timer readings
read add. heat
delay
6.2