Commissioning the heat pump
Drying program for fl oor tile
When the heat pump has been installed in a newly built house with fl oor
heating, the Drying of fl oor tile function can be used.
The function is designed to slowly heat up the fl oor tile during a set
number of days. The temperature is then maintained for a set number of
days, to fi nally allow the tile to cool slowly for a set number of days. The
heat pump works during drying operations with the hysteresis set in the
display P1.4.
It is also possible to operate drying program with only additional heat.
Here you set how many days you want the heating phase to last.
Here you set how many days you want the fl oor heating system to maintain
the maximum drying temperature.
Here you set how many days you want the cooling phase to last.
Here you set the start and stop temperatures for the drying program.
Here you set the maximum temperature that the drying program should
work at.
The function is activated and deactivated here. Drying program.
Temperature
During drying operations the heat
pump does not produce any hot water
and is not affected by timer controls.
Once the drying program has fi nished
the heat pump returns to normal mode.
When an extra shunt group is installed,
it works according to the normal heat
curve. The mixing valve must be
opened manually when you want this
circuit to be included in the drying
program too.
Time
70
Note
Drying program
No of days
for heating
5.14.1
Return
Select
Drying program
No. of days for
max temp
5.14.2
Return
Select
Drying program
No. of days for
temp + cold 5.14.3
Return
Select
Drying program
Start/Stop
temperature
5.14.4
Return
Select
Drying program
Max temp. during
drying
5.14.5
Return
Select
Drying program
Active
drying
5.14.6
Return
Select