Wiring Diagram Cav Starter With Repeater Relay - Perkins 4006 User Handbook Manual

Diesel engine
Table of Contents

Advertisement

WIRING DIAGRAM, CAV STARTER WITH REPEATER RELAY FOR REMOTE OR
AUTOMATIC START
Key
(Fig. 49)
1. Charge alternator
2. Oil pressure switch
3. Resistor
4. Water temperature gauge
5. Oil temperature gauge
6. Oil pressure gauge
7. Ammeter
8. Tachometer
9. Fuse
10.Governor actuator
11.Repeator relay
12.Aux terminal gives a battery negative
signal fully energised
13.Water temperatur sender
14.Oil temperature sender
15.Oil pressure sender
16.Oil pressure sender
17.Key switch if required
18.Starter motor
19.Start relay
20.Fuel solenoid relay
Fig. 49
50
21.Fuel solenoid energised to run
45.0 Amps inrush
0.75 Amps holding
22.Combined engine faults switch
23.Water temperature
24.Oil pressure
25.Magnetic pick-up
26.Engine flywheel
27.24 volt starting batteries
28.Typical terminal block
29.Two switch speed unit
30.Switch 2 overspeed
31.Switch 1 speed ref
32.To enable engine to run immediately on
depressing start button both FPS and GOV+
must be fed 24 volt +ve. To stop break thus
+ve supply
33.Speed trim pot
34.If speed trim pot is not required remove
and connect thus
35.Wire sizes
4006/8 Diesel, May 1998