The POLR instruction also resets and clears this unit's
Processor Fault Interrupt signal and the error status regis-
ter. In addition to the operation code of X'4F', bits 15,
16,
and
17
must be coded as 011 , respectively.
Affected: (R), CC1, CC2, CC3
Condition code settings for the POLR instruction are:
2
3 4
Result of POLR
o
0
0
-
Processor fault interrupt not pending.
o
AID
o -
Processor fault interrupt pending.
o -
Unit address not recognized.
ACKNOWLEDGE INPUT/OUTPUT INTERRUPT
(Word index alignment, privileged)
ACKNOWLEDGE INPUT/OUTPUT INTERRUPT is used to
acknowledge an input/output interrupt and to identify the
I/O subsystem (processor, device controller, device) that
is causing the interrupt and why.
If more than one I/o
subsystem has an interrupt pending, only the subsystem
with the highest priority will respond to the AIO. Bits 18-
23 of the effective virtual address of the AIO instruction
(normally used to specify the cluster and unit addresses of
the I/O address field) must be coded 000000 to specify
the standard I/O system interrupt acknowledgment (other
codings of these bits are reserved for use with special I/O
systems). The remainder of the I/o selection code field
(bit positions 24-31) are not used in the standard I/O in-
terrupt acknowledgment (the address of the interrupt source
is a part of the response from the standard I/O system to
the AIO instruction).
Standard I/O interrupts are program controlled via the con-
trol flags (IZC, ICE, IUE, HTE, and SIL) within the I/o
command doublewords (lOCOs) that comprise the command
list for the I/o operation. If a particular flag is coded as
a 1 and if the corresponding condition occurs within the
I/O operation, then an I/O interrupt is requested (e. g. , if
the IZC flag is set to 1 and if the byte count for the I/O
operation has been decremented to zero, then an I/O
interrupt is requested by that I/o subsystem to indicate the
end of that I/O operation; if the IZC flag is coded as a 0,
no I/O interrupt is requested as a result of the byte count
bei ng decremented to zero).
If two or more flags are
coded
to ClJuse lJn !nterrupt for two
or more conditions, an interrupt is requested whenever any
of the IIflagged
ll
conditions is detected.
For some conditions (transmission errors, incorrect length),
two or more flags must be properly coded (see Chapter 4
for further details on lOCOs).
140
Input/Output Instructions
Some error conditi ons (e. g., parity error on reading command
doubleword) will unconditionally cause an I/O interrupt.
The various conditions which may result in an I/O inter-
rupt, the coding of the corresponding control flags within
the lOCO, and the bit position within the status word (re-
turned to register R) that indicates the presence (1) or ab-
sence (0) of that interrupt condition are listed below:
Condition
Zero byte count
Channel end
T~ansmission
memory error
Write lock violation
Incorrect length
Memory address error
I
lOP memory error,
lOP control error, or
device connection address
parity error
T ransm i ssi on data error
Unusual end
lOP halt
Control Flags
Coding
IZC
=
1
ICE = 1
IUE = 1, HTE = 1
IUE =
1,
HTE = 1
IUE =
1,
HTE =
1
and SIL = 0
) (no flag needed)
IUE=l,HTE=l
IUE = 1
IUE = 1
Status
Bit Set
10
11
12
12
8,
12
12
9,
12
12
12, 14
Interrupts may also be requested by certain I/O devices
when they execute specific orders (e. g., when a magnetic
tape unit executes a Rewind and Interrupt order).
Refer
to the applicable peripheral reference manual for further
details.
When a device interrupt condition occurs, the lOP forwards
the request to the interrupt system I/o interrupt level. If
this interrupt level is armed: enabled: and not inhibited;
the BP eventually acknowledges the interrupt request and
executes the XPSD instruction in main memory location
X ' 5C', which normally leads to the execution of an AIO
i nstructi on.
For the purpose of acknowledging standard I/O interrupts,
the lOPs, device controllers, and devices are connected in
a preestablished priority sequence that is customer-assigned
and is independent of the physical locations of the portions
of the I/o system in a particular installation.
If the R field of the AIO instruction is 0, the condition code
;s set but the genera! iegistsi is not affected.
If the R field of AIO is not 0, the condition code is set and
register R is loaded with the following information.