Processor Interface detected parity error on
returned status and/or condition code. The
result of the TDY is indeterminate.
o
0
I/O address not recognized, TDY not ac-
cepted, and status information returned to
the general registers is incorrect.
o
No I/o address recognized and TDY aborted
because an error detected when the lOP at-
tempted to read and transfer the TDY param-
eters (device/device controller address and
R field information) from the BP to the lOP
via main memory.
No status information re-
turned to general registers.
If CC4
=
1, the MIOP is in the test mode and the meaning
of the condition code during a TDY is:
2
3 4
Meaning
0
0
0
Unit is performing an Order Out operation.
0
0
Unit is performing an Order In operation.
0
0
Unit is performing a Data Out operation.
0
Parity error detected by Processor Interface
on returned status and/or condition code. The
result of the TDY is indeterminate.
0
Unit is performing a Data In operation.
BCF detected while unit performing a Data
In operati on.
HIO
HAL T INPUT/OUTPUT
0/Vord index alignment, t privileged)
HALT INPUT/OUTPUT causes the addressed device to im-
mediately halt its current operation (perhaps improperly,
in the case of magnetic tape units, when the device is
forced to stop at other than an i nterrecord gap). If the
device is in an interrupt-pending condition, the condition
is cleared.
tWhen indexing operation code 4F instructions (HIO; RIO;
POLP, POLR), the programmer must make certain that the
summation of the contents of the index register and the I/o
address (bits 18-31 of the instruction word) does not affect
bits 15-17. When indirect addressing is used, the contents
of the indirect address location (bits 15, 16, and 17) must
specify the desired operation code extension.
138
Input/Output Instructions
If the R field of the HIO instruction is 0, the condition
code is set, but no general registers are affected.
If the R field is an odd value, the condition code is set
and the following information is loaded into register R.
If the R field of HIO is an even value and not 0, the
condition code is set, register Ru 1 is loaded as shown above,
and register R contains the following information.
This information shows the status of the addressed I/O sub-
system at the time of the halt. The byte count field shows
the number of bytes remaining to be transmitted to or from
memory. Other fields are described in Table 14-17.
The HIO instruction must have zeros in bit positions 15, 16,
and 17 to differentiate it from the RIO, POLP, and POLR
instructions, which also have X'4F' as an operation code
(bits 1-7).
Affected: (R), (Ru1), CC
If CC4
=
0, the MIOP is in a normal mode of operation
and the meaning of the condition code during an HIO
instruction is:
2
3 4
Meaning
o
0
0
0
I/O address recognized, HIO accepted, de-
vice controller not busy at time of HIO,
and status information in general registers is
correct.
o
0
0
For R.MP,
I/O
address recognized, HIO ac=
o
o
cepted, and device controller not busy at time
of HIO; but status information ingeneral reg-
isters may be correct. For MIOP, not possible.
o
0
I/O address recognized, HIO accepted, and
device controller busy at the time of the HIO,
and status i nformati on is correct.
o
For RMP, I/O address recognized, HIO ac-
cepted, and device controller busy at the time
of the HIO; but the status information in the
general registers may be incorrect. For MIOP,
not pO$5ible.
o
0
0
Not possible.
o
0
Processor Interface detected parity error on
returned status and/or condi ti on code. The
result of the HIO is indeterminate.