Carbolite MRF 16 Installation & Operating Instructions Manual page 31

Table of Contents

Advertisement

Press scroll
Press scroll
Press scroll
Press scroll
Press scroll
Press scroll
Press scroll
Press scroll
Press scroll
Press scroll
down
to fill the first square in
Press scroll
For segments 2,3,4 and 5 enter the following parameters and values:
Segment 2: Dwell, Duration 1:00:00, Micro % 100, Event outs
(Segment 3: Call, Call Prog 3, Call Cycles 1. Only on multi program controllers)
Segment 3(4): Step, target set point 800°C, Holdback High, Micro %100, Event outs
Finish the program with an End segment:
Segment 4(5): End, Dwell, Event outs
To run the program:
Press page
and scroll
Press RUN/HOLD twice
To pause (hold) the program:
Press RUN/HOLD once
To reset the program:
Press RUN/HOLD once to pause (hold) it
Press RUN/HOLD for 3 seconds.
MF 55-GB 1.21
Value is displayed. Press up
Holdback
Ramp Units is displayed. Press up
Cycles is displayed. Default '1'
Segment 1 is displayed
Segment Type is displayed. Press up
Target SP is displayed. Press up
Duration is displayed. Press up
Holdback Type is displayed. Leave at default setting 'Off'.
Micro% is displayed. Leave this as it is.
Event outs
is displayed. The first square will be flashing. Press up
The second square will flash. Leave this square blank
at the same time return to the home page.
or down
or down
or down
.
or down
to set to '3' degrees
to set to 'Min'
or down
to select 'Time'
to set to '1200' degrees
to set to '2:25:00'.
.