9.26
ALLOW OWN USER
CODE CHG? NO YES
9.27
PANIC SUPRVISION:
NO YES
9.28
ENTER WEATHER
ZIP CODE:
XR500 Series Programming Guide

Allow Own User Code Change

This option allows users without user code authority to change their own user code.
When YES is selected,the User Code menu displays USER CODE: ***** at the keypad to
allow that user to change their own code. If NO is selected, the user cannot change their
personal user code. Default is NO.
Panic Supervision
Select YES to enable a 30 day supervision of the Model 1145-1-B-PSV key fob.
Default is NO.
This option allows a key fob that is lost or has a dead battery to be identified at the
Central Station host automation system as a missing transmitter, without the need to
apply a supervision time in zone information programming. SCS-VR Version 1.3.6 or higher
is required to receive 1145-1-B-PSV supervision messages through the XR500 panel.
The 1145-1-B-PSV key fob supervision message is communicated to SCS-VR using all
XR500 communication paths where Panic Test is YES within Advanced Communication
programming. A supervision message is automatically sent from the key fob to SVS-VR
every four hours, resetting the 30 day countdown timer for that key fob serial number.
If the 30 day timer expires for a key fob serial number, SCS-VR will generate a zone
missing message to the host automation system. For the application where the key fob is
programmed into several XR500 Version 210 or higher panels, a supervision message sent
through any XR500 into which the key fob is programmed will satisfy the 30 day timer.
The SCS-VR zone missing message to host automation will be for the last panel account
number where the key fob successfully communicated a supervision message to SCS-VR.
The key fob MISSING is not displayed or recorded at the XR500 control panel.
In addition, this option allows for manual testing of 1145-1-B-PSV key fobs during Walk
Test (8144) or Panic Test from the user menu. A key fob that is successfully activated
during these test modes will cause an increment to the keypad display TRIPS counter and
a Verify message is sent to SCS-VR for that zone. For those 1145-1-B-PSV key fobs that
are programmed into the panel but not manually tested, a Fail message is NOT displayed
at the keypad and is not sent to SCS-VR.
Weather Zip Code
This option allows local U.S.A. weather updates to display on the keypad. Enter the
0
zip code of the user at this prompt. When no number is entered weather conditions
are not displayed. Default is 0 (zero).