Device Setup - Digital Monitoring Products XR500 Series Programming Manual

Table of Contents

Advertisement

6.1

DEVICE SETUP

6.2
DEVICE NO:-
6.3
* UNUSED *
6.4
TYPE: KEYPAD
DOOR KPD FI EXP
6.5
DEVICE COMM TYPE
KPD-BUS
DEVICE COMM TYPE
KPD-BUS NETWORK
DEVICE COMM TYPE
KPD-BUS WIRELESS
6.6.
SERIAL#: XXXXXXXX
6.6.1
SUPRVSN TIME: 240
SELECT MINUTES:
0
60
6.7
ACCESS AREAS:
1
2
3
5
6
7
XR500 Series Programming Guide
Device Setup
Device Setup
This section allows you to define the XR500 Series panel physical configuration. You can
install and address up to sixteen supervised devices on the keypad data bus.
Device Number
Enter the device number of the keypad you are programming. The valid range is 1-16. If
using a wireless keypad, program the device number in the Status List Auxiliary 1 Zones
programming option to display wireless keypad troubles.
Note: After you program each option for the first keypad, repeat these programming
steps for each additional keypad.
Device Name
A device name must be given to each device in the system. To add a device name, press
any Select key. The default device name (DEVICE X) displays. Select COMMAND to accept
the default name or press a Select key to enter a new name up to 32 alphanumeric
characters. Press the COMMAND key.
To remove a device from the system, delete the device name by pressing any Select key,
then press the COMMAND key. The panel automatically programs the name as * UNUSED *.
Device Type
This section allows you to select a device type for the selected device number.
DOOR - The device is an access control device and is either a keypad using door strike
functions or a Wiegand Interface Module.
KEYPAD - The device is a keypad.
FIRE - The device is a 630F Remote Annunciator.
EXPANDER - The device is a Zone Expansion Module.
Note: The following options display based on device type selected:
Device Communication Type
For a Device Type of DOOR, select KPD-BUS to communicate with the device on
the keypad bus or select NETWORK to communicate with the device using a network
connection. Default is KPD-BUS.
For a Device Type of KEYPAD, select KPD-BUS to communicate with the device on
the keypad bus or select WIRELESS to communicate with the device using a wireless
connection. Default is KPD-BUS.
Serial Number
Note: This option only displays if Device Type is KEYPAD and Device Comm Type is WIRELESS.
Enter the eight-digit serial number found on the wireless keypad.
Supervision Time
Note: This option only displays if Device Type is KEYPAD and Device Comm Type is WIRELESS.
Press any top row key to select the supervision time required for the device. Press
COMMAND to accept the default time. Default is 240 minutes.
Press the Select key under the required number of minutes. The device must check in at
240
least once during this time or a missing condition is indicated for that device. Zero (0)
indicates an unsupervised wireless keypad.
Note: When the panel is reset, panel is powered down and powered up, or programming
is complete, the supervision timer restarts for all wireless keypads.
Access Areas
Press the COMMAND key to program Access Areas. To select an area, enter the area
4
number using the digit keys on the keypad. When an area is selected, an asterisk appears
8
next to the area number. Enter the number again to deselect the area. Press COMMAND
to display the next set of areas. Refer to the Multiple Displays section at the beginning of
this document.
Users must have matching access area numbers assigned to their code to receive a door
access at this device.
If you do not enter any area numbers, all users with Door Access authority receives a door
access without regard to schedules. If the user code is programmed for Anti-Pass YES, then
the user is logged into all matching areas. This user is not allowed to access these areas
again until they have egressed the area. See Egress Areas.
Device Setup
Digital Monitoring Products
15