Preparing for Operation
Set Values
Set value
0
Deceleration stop in deceleration time 1 set with n020
1
Free running stop
2
Deceleration stop in deceleration time 2 set with n022
3
Continuous operation with warning
Note If n034 is set to 3, the Inverter will display "OH1" when the temperature of the heat sink reaches
approximately 90°C and the Inverter will continue running. If "OH1" is displayed, use a cooling fan
or air conditioner to cool the Inverter. The Inverter will detect the heat sink overheat warning OH2
if the temperature further rises after "OH1" is displayed. The Inverter will stop running immediately
after OH2 is detected to protect its power module from damage so that the motor will coast to stop.
n035
Multi-function Input 1 (S2)
Setting range
0 to 24
n036
Multi-function Input 2 (S3)
Setting range
2 to 24
n037
Multi-function Input 3 (S4)
Setting range
2 to 24
n038
Multi-function Input 4 (S5)
Setting range
2 to 24
n039
Multi-function Input 5 (S6)
Setting range
2 to 27
• The parameters n035 to n039 can be set to the following.
• Each of the set values of n035 to n039 must be unique.
3-66
Description
Unit
---
Unit
---
Unit
---
Unit
---
Unit
---
Chapter 3
Default setting
0
Default setting
2
Default setting
4
Default setting
9
Default setting
10