Diagnostic Table - Fisher & Paykel Ecosmart GWL15-US-96200 Service Manual

Fisher & paykel ecosmart phase 7 electronic washing machines
Table of Contents

Advertisement

517792A
4.9

Diagnostic Table

To use this table, firstly enter Diagnostic Mode (Refer to Section 4). The different levels of
information can be extracted by using the Spin Speed up and down buttons.
Diagnostic
Spin Speed LEDs
Level
Fast
0
OFF
1
OFF
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
ON
9
ON
10
ON
11
ON
12
ON
13
ON
14
ON
15
ON
Diagnostic mode 0, Last User Warning Number:
When in this level, use the binary count on the Wash Progress LEDs as used to obtain the last
fault data. Use the chart below to identify which was the last user warning.
Binary Count
0
1
2
3
4
5
6
7
Diagnostic mode 1: Last User Warning Cycle Position
To find out which stage in the cycle the last user warning occurred, use this level. A LED on the
wash progress LEDs will identify the stage, ie if the user warning was suds (in diagnostic level 0)
st
and the 1
Rinse LED was lit in this level, this was the stage in the cycle where the user warning
occurred.
Diagnostic mode 3: Last fault data
This level is sometimes referred to as the detailed fault code. By adding up the LEDs on the wash
progress in binary form (Refer to Section 4), this will relate to a fault code (fault codes are
contained in the last section of this manual). If there are no LEDs lit, a fault code hasn't occurred
in the last 8 cycles.
Diagnostic mode 5&6: Cycle count at last fault (Low byte, High byte).
These levels will indicate how many cycles ago the last fault occurred. Even though the last fault
gets wiped from diagnostic level 3 after 8 cycles, the cycle where the fault occurred is permanently
stored in the memory.
The low byte refers to binary numbers from 1 through to 128. The high byte Refers to numbers
from 256 though to 32768. It always pays to check the low and high bytes.
Med
Slow Hold
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
User Warning
No warning
No taps
Overload
OOB
Suds
No Hot
No Cold
Agitate overloaded
Diagnostic Info Displayed
Last User Warning Number
Last User Warning Cycle Position
Factory use only – Not applicable to the field
Fault Code at last fault (if within the last 8 cycles)
Factory use only – Not applicable to the field
Cycle count at last fault (low byte)
Cycle count at last fault (high byte)
Cycle position at last fault
Water Temp (deg C)
Cycle count (low byte)
Cycle count (high byte)
Motor speed (RPM)
Water Level
EEPROM version number
Factory use only – Not applicable to the field
Factory use only – Not applicable to the field