Secondary Source: Motor Control Module has failed to read the temperature. Check
Action:
238. (11101110) Lid Lock Fail In-Line Test (1)
Final on line tests, final check before going to the field.
239. (11101111) Lid Lock Fail In-Line Test (2)
Final on line tests, final check before going to the field
240. (11110000) Hall Out Of Order. RPS Fault
Same as previous Hall Error faults See fault code130 for directions.
241. (11110001) Function Time Out
Display crashed.
Primary Fault:
Action:
Secondary Fault:
Action:
243. (11110011) Stepper Test Failure
Rotor Position Sensor fault. The Motor Control Module has attempted a motor step test
and found the motor has not stepped to the correct position.
Primary Fault:
Action:
252. (11111100) Bridge Test Failure
The Motor Control Module has tested the motor bridge electronics and sensed current
when there should not have been any.
Primary Fault:
Action:
Replace the Thermistor (temperature sensor).
connections.
Replace Motor Control Module if connections look fine and the fault
still occurs.
Display Module has failed.
Replace Display Module.
Motor Control Module has failed.
Replace Motor Control Module.
Wiring.
See Fault codes 53 and 54.
Motor Control Module
Replace Motor Control Module