F 50 Motor Stalls And Heater Is On For 3 Seconds; F 55 Overriding Time Limit Exceeded, Approx. 180 Min - Miele T 9800 Descriptive Technical Documentation

Hide thumbs Also See for T 9800:
Table of Contents

Advertisement

090-14
3.12

F 50 Motor stalls and heater is on for 3 seconds

Symptom
The motor for drying air/cooling air and drum drive (M5) stalls.
The fault occurs in the operating mode: Program stop, cooling air phase,
intermittent buzzer tone.
Opening and closing the door deletes this fault code indication.
Cause
This is an internal fault of the Control/Program/Power module (1N1, EPWL).
Remedy
A Check the drying air, cooling air and drum drive motor (M5).
A Replace the Control/Program/Power module (1N1, EPWL, Single Board
Control)
3.13

F 55 Overriding time limit exceeded, approx. 180 min

Symptom
Only in residual moisture programs.
This fault occurs in the normal operating mode: Program stop, cooling air phase,
intermittent buzzer tone for 2 minutes.
The LED Anti Crease/End lights up solid.
The Fault/Vent LED lights up solid.
Opening and closing the door deletes this fault code indication.
The safety time has been exceeded, refer to 090 2.4 Overriding time control.
Cause
Laundry too wet, or dryer overloaded.
Remedy
A Spin the laundry more thoroughly in the washer, or reduce the laundry load.
Cause
Laundry is electrically conductive (low ohmic), due to a metal zipper for example.
This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation
DTD no. 12-9800
05.12.2006, US_am