031-12
A For the permanent assembly, give the connecting nut another 1/4 turn with a
17 mm open-end wrench (19 Nm ± 1 Nm), maintain counter pressure on the
double nipple with a second 17 mm open-end wrench.
Fig. 11
A Connect the 2 plugs and the ground lead to the gas regulation valve.
A Attach the right side panel.
A Attach the front panel.
A Attach the fascia panel.
A Attach the dryer lid.