DTD no. 12-9800
3.8
F 1 Short circuit in NTC temperature sensor heating/drying
(2R30)
Symptom
Program stop, cooling air phase, buzzer intermittent tone.
Only the timed program cold air still works.
The LED Rotary iron flashes.
The LED Clean air paths flashes.
Opening and closing the door deletes this fault code indication.
Cause
Short circuit in temperature sensor heating/drying (2R30) (> 480 °F).
Remedy
A Check the lines and plugs of the temperature sensor heating/drying (2R30)
for short circuit and open circuit.
A For temperature sensor heating/drying characteristic curve, refer to 030 Table
3.
3.9
F 2 Open circuit in NTC temperature sensor heating/drying
(2R30)
Symptom
Program stop, cooling air phase, intermittent buzzer tone.
Only the timed program cold air still works.
The LED Rotary iron flashes.
The LED Clean air paths flashes.
Opening and closing the door deletes this fault code indication.
Cause
Open circuit of temperature sensor heating/drying (2R30) (< 68 °F), evaluation
only after the heater has been run for at least 1 minute.
Remedy
A Check the lines and plugs of the temperature sensor heating/drying (2R30)
for short circuit and open circuit.
A For NTC temperature sensor heating/drying characteristic curve, refer to 030
Table 3.