F 3 NTC temperature sensor drying air (1R30)
Symptom
Program stop, cooling air phase, intermittent buzzer tone.
Only the timed program cold air still works.
The LED Hand iron flashes.
The LED Clean air paths flashes.
Opening and closing the door deletes this fault code indication.
Cause
Short circuit (> 320 °F) in temperature sensor heating/drying (1R30).
Remedy
A Check the lines and plugs of temperature sensor drying air (1R30) for short
circuit and open circuit.
A For temperature sensor drying air (1R30) characteristic curve, refer to 030
Table 4.
3.11
F 4 NTC temperature sensor drying air (1R30)
Symptom
Program stop, cooling air phase, intermittent buzzer tone.
Only the timed program cold air still works.
The LED Hand iron flashes.
The LED Clean air paths flashes.
Opening and closing the door deletes this fault code indication.
Cause
Open circuit (< - 60 °F) in temperature sensor drying air (1R30) ./
XXXTemperaturfühler-Prozessluft (1R30), Unterbrechung (< - 15 °C).
Remedy
A Check the lines and plugs of temperature sensor drying air (1R30) for short
circuit and open circuit.
A For temperature sensor drying air (1R30) characteristic curve, refer to 030
Table 4.