3.2

LED Clean air paths lights up solid

Symptom
Normal program run.
Fault indication at the end of the cooling air cycle.
Insufficient air detection, refer to 090 2.5 Insufficient air detection.
Opening and closing the door deletes this fault code indication.
Cause
Air paths are clogged.
Remedy
Note
Clean the lint filter, refer to operating instructions.
A Clean the lint filter in the door casing and in the fill ring.XXX
A Clean the air paths in the dryer.
Cause
The fault message Clean air paths is issued prematurely.
Remedy
A Adjust the fault message indication Clean air paths , refer to operating
instructions, or Programming mode summary, 090 4.1.