6.3. Boiler tightness.

It is important to assure boiler tightness, mostly door tightness. Leaks cause that exhaust gases
escape to boiler room but most importantly it may leads to uncontrolled burning in the boiler. To
assure door tightness, silicone rope of upper door needs to be controlled and in case of damage
of silicone coat – replaced. Rope in bottom door must be greased ( at least once a month) with oil
or graphite grease.
To adjust boiler door one should
a) Remove the door
b) Loosen screw
c) Rotate both hinges 360°
d) Screw up the nut.
ATTENTION!
Door adjustment needs to be done on both hinges!

6.4. Fan maintenance.

It is important to keep the fan cleaned. Keeping the fan blades cleaned directly influences boiler
and pump lifespan. It is recommended to take off front fan cover to remove ash that may leads to
fan power decrease and may damage the fan. It is acceptable to clean the fan blades with brush
with soft bristle.
Pic.4 Boiler tools.
blocking nut
11