Main construction parameters' listing
Power
Power range
Efficiency
Boiler class (EN 303-5)
Boiler weight
Water capacity
Volume of loading chamber
Loading hole width/lenght
Burning period
Wood logs lenght
Humidity
- recommended
Power range for every kind of fuel:
Billets
Fuel usage for power:
- nominal
- minimal
Max working pressure
Minimal return water temperature
Flow resistance
- t = 20 K
- t = 10 K
Temperatures setting range
Protection level of controller
Voltage/Frequency
Auxiliary power
Exhaust gases parameters (at nominal
power):
- temperature
- stream
Exhaust gases parameters (at minimal
power):
- temperature
- stream
Required chimney draft
Min water pressure in cooling coil
Cooling coil water temperature
Recommended capacity of accumulation
tank
kW
18
25
kW
7-18
10-25
%
kg
546
546
3
dm
75
75
l
75
75
3
dm
120
120
l
120
120
mm
260/432
260/432
h
cm
50
50
%
kW
7-18
10-25
kg/h
6,8
8,2
3,9
5,7
bar
°C
mbar
1,2
1,4
mbar
4,0
4,3
°C
V/Hz
W
50
50
160
160
°C
0,0066
0,0088
kg/s
160
160
°C
<0,0066
<0,0088
kg/s
mbar
Pa
bar
°C
l
750-1500
1000-2000
40
60
16-40
24-60
91
3
634
1037
93
180
93
180
185
310
185
310
260/432
285/580
285/580
7-12
50
75
15-25
16-40
24-60
10,1
15,1
7,9
11,9
3
60
1,6
1,7
4,9
4,9
60-97
IP 40
230/50
50
100
160
160
0,0144
0,0216
0,0272
160
160
<0,0144
<0,0216
<0,0272
0,15-0,20
15-20
2
10
2000-3000
3000-4000 4000-5000
80
32-80
1242
205
205
465
465
100
32-80
19,8
15,8
1,6
4,8
100
160
160
19

Hide quick links: