ATTENTION!
- Setting blow-through on „0" will deactivate blow-through,,
- Above 98 °C blow-through is turned off not to overheat the boiler.

Remote control

Controller is adjusted to install remote control „EKOSTER CONTROL" that enables to control and
change the boiler's temperature, displays of pump condition and mode START-STOP, at the same
time remote control can activate alarm in case of temperature sudden increase to alarming level.
Remote control with 10 or 15 meters cable is an accessory appliance.
Service mode
Service mode is for settings changes. To enter service mode:
• turn off controller,
• turn on and during controller's software displaying (ex. 3.4) press and hold
parameter "HI" will display.
Controller displays in turn symbol and its value.
parameter value and button
Parameter order:
• „HI" temperature's hysteresis (setting range: 2 – 9 °C) how much temperature must fall from
set temperature to turn the fan on.
• „Po" temperature of pump activation - preset 65°C (setting range: 65-90°C), after room
thermostat connection, change temperature below 65°C, till „rP" parameter appears on
display– Ekoster based on signal from room thermostat will automatically control pump's
operation.
• „DT" temperature's difference from operation threshold: at what temperature's difference
controller will enter
set temperature = 70°C, after falling below 50°C
( temperature decreased below DT parameter) controller will wait 30 minutes and will turn off
fan signaling it with
• „┌ ┐ ": fan power in percentages (3: 30% - 10:100%)
ATTENTION!
It is recommended to set DT=20 HI=2°C and boiler's temperature 90°C for connection
with accumulation tank.
6
,
buttons enables to change current
is for moving on to next parameter:
or
status (setting range: 10-30°C) for example DT=20,
diode.
button until