Operation description
After switching on, controller is in
starts after pressing
threshold – temperature difference between set temperature and DT parameter set in the service
menu. Status
below operating threshold. CONTROL socket which is located at the back panel of the controller
is for connection of remote control EKOSTER CONTROL.
Buttons
and
służą do zmiany nastaw. During boiler operation, pressing
possibility to change desired boiler's temperature. Pressing and withholding button causes
increase of speed of temperature changing
Pressing button
causes:
• temperature below operating threshold:turning on/off of the controller signaled with diodes
or
• at temperature above operating threshold:fan operation blockade signaled by blinking
, diode, which makes possible to stoke the boiler. Return to automatic operation after
pressing
button.
ATTENTION!
Displaying „Er" on the controller informs about temperature increase above 99 °C,
below -9 °C or boiler sensor damage. To secure the boiler till sensor replacement,
pump will be automatically activated.
COMFORT SYSTEM
COMFORT SYSTEM function in controller prevents pump's rotor from stone deposition.
Controller automatically activates pump after heating season for 30 seconds every 14 days.
Pump operation in this mode is signaled with flashing POMPA
1 minute since controller's activation. Pump activation in this mode causes that 14 days period is
counted at the beginning.
Freezing and overheating function
Controller enables to turn on circulation pump In case if temperature drops to 4 °C or lower.
Exceeding 97°C causes fan to turn off and circulation pump activation. Boiler overheating is
signaled with flashing
of overheating, eliminate and turn on the boiler pressing
permanently In case of boiler sensor damage.
Blow-through
• Press
and hold for 3 s till diode
• przyciskami
,
• Press
dtill diode
• With buttons
,
• Press
.
From now on controller at temperatures higher than set one will activate blow-through.
, , which is signaled by adequate diode. Operation
or automatically, when boiler's temperature increases above operating
is automatically activated after 30 minutes since temperature decrease
,
diode. In such a case it is recommended to determine cause
are for blow-through time setting in seconds,
starts blinking,
set blow- through pause in minutes,
diode. Function activates after
button. Pump is activated
starts blinking,
or
causes
5