Bosch D7212GV2 Release Notes page 9

Version 7.07
Hide thumbs Also See for D7212GV2:

Advertisement

To be ANSI/SIA CP-01 compliant, the
Fixed Passcode Length feature must be
enabled. For backward compatibility, Fixed
Passcode Length is disabled by default
If you change the Fixed Passcode Length
value to 4 or greater, you must also
change the default Service Passcode to
match the new length.
Remote Arm/Disarm Output
Prompt:
Remote Warning
When enabled, this feature uses the Alarm Bell output
to annunciate the arming and disarming of an area by
remote means, such as by keyswitch, key fob, or
remote software (RPS, BIS Security Engine). When
arming occurs, the output pulses for two seconds.
When disarming occurs, the output pulses ON, OFF,
ON, OFF for two seconds each.
Abort Window
Prompts:
CC# Abort
Display, P
Abort Window
This feature is always enabled, but it only applies to
intrusion alarm events generated by points that have
P# Alarm Abort
set to Yes and
to No. When an intrusion alarm event is annunciated,
the user has the duration of time programmed in the
Abort Window
prompt to enter a valid passcode to
prevent the alarm event from being transmitted to the
central station. When transmission is aborted
successfully, any keypad with
to Yes shows ALARM NOT SENT.
Cancel Window
Prompt:
CC# Cancel Display
This burglary alarm cancel window is enhanced by an
optional keypad display. When
Cancel Report
is set to Yes and
alarm silence operation after event transmission
displays CANCEL RPT SENT on the keypad. The
burglary alarm cancel window duration is the time
A# Alarm Bell
programmed in the
© 2007 Bosch Security Systems, Inc.
# Alarm
Abort,
P## Invisible Pt
set
CC# Abort Display
set
CC# Cancel Display
is set to Yes, an
prompt.
D7212GV2 Release Notes for Version 7.07
Duress Passcode
Duress Type
Prompts:
L## Send Duress
A new duress option is available that allows any
passcode with the
L# Send Duress
Yes to always send a Duress Alarm event upon entry.
This feature allows the control panel to have uniquely
dedicated passcodes for all users. Additionally, when
this feature is enabled, the Passcode +1 and +2
features are disabled for compliance with SIA CP-01-
2000 regulations.
Swinger Shunt Enhancement
Swinger Count
Prompt:
The Swinger Bypass feature is enhanced to allow a
variable number of faults before automatically
bypassing a point. When a point with
Bypass
set to Yes is faulted the number of times
Swinger Bypass Count
programmed in
automatically bypassed.
Power-Up Standby
When the control panel is powered up, or the system
is rebooted, all points are temporarily bypassed for 60
seconds. This feature is always enabled and has no
configuration parameters.
Walk Test Enhancements
The Walk Test procedure is enhanced to provide
more user feedback. The Walk Test now indicates that
the menu is ready to time out, and clearly notifies the
user at all keypads in the area of operation when a test
is in progress. Additionally, the Walk Test procedure
issues point trouble conditions for any 24-hour or fire
points that remain off-normal when the Walk Test
menu exits. After the system annunciates the trouble
condition, faulted points are automatically swinger
shunt bypassed regardless of the point index settings.
These enhancements are always enabled and have no
configuration parameters.
Page 9