Corrections and Changes
2.1
Version 7.07
The following corrections and changes were made in
the D7212GV2 Control Panel since Firmware 7.06:
The RPS port number prompt was renamed and
moved from GV2AUX→ SDIRPS/ENHANCED
CONF → BasePortNumber to GV2AUX → SDI
RPS PARAMETERS → RPS Port Number in
GV2AUX v1.03.
The Anti-Replay enable prompt for the Anti-
Substitution feature was renamed and moved
from GV2AUX → MISCELLANEOUS →
EnableAntireplay to GV2AUX →
ENHANCED COMM → Path #AntiReplay in
GV2AUX v1.03. The value in the
EnableAntireplay prompt when using GV2AUX
v1.02 or older shows in the
prompt.
When you upgrade a D7212GV2 with
firmware version 7.07 or later, you must
enable the Anti-Replay option individually
for each enhanced communication path if
you are using this feature. Previously, one
prompt applied to all destination paths.
Changes were made to improve the reliability of
the Time Sync feature. When enabled, this feature
no longer causes intermittent erroneous skipping
or duplication of skeds. This corrects the issues
described in the G-GV2 Series Skeds Technical
Bulletin from October 11, 2006 (P/N: TBI 10-5-06
1 B G-GV2 Series Skeds).
For optimal keypad user interface performance,
ensure that any D1260 or D1260B Keypads
connected to the system are running firmware
version 1.04 or later. An update kit (P/N: R19-
D1260-0104) is available from Customer Service:
(800) 289-0096.
Changes made prevent the recent close alarm
feature from interfering with panic alarm reports.
Now, a panic alarm (an alarm generated by a 24-
hour point) is reported as a Burglar Alarm in any
arming state. This corrects the issue described in
the SIA CP-01 and Panic Alarms Technical Bulletin
(P/N: F01U064901-01).
F01U009079-04
Path 1Anti-Replay
D7212GV2 Release Notes for Version 7.07
Page 2
Changes made prevent corrupted data account
codes for systems that communicate with BIS 2.0
Security Engine. These changes are only
compatible with BIS Security Engine v2.1.1271 or
later. This addresses the issues described in the
BIS SEE and GV2/G Series Technical Service Note
(P/N: F01U073249).
Changes made allow the Relay Latches on point
P## Relay Response Type
fault option for the
feature to reset when a passcode is entered even
when the associated point has not returned to
normal. This correction does not apply to
invisible points.
Corrections made to the View Points menu in the
D1260 and D1260B user interface now allow the
display to advance even when there is only one
viewable point in the area. This addresses the
issue described in the Unresponsive D1260 Keypad
Technical Bulletin (P/N: TBI 02-09-07 01).
Corrections made now allow the use of any
enhanced communication path in any route
group. For example, Enhanced Communication
Path 2 can be the primary destination for Route
Group 4 with Phone Number 3 as backup.
However, the primary and backup paths for any
route group must be different.
Changes made now allow the clearing of the
alarm memory when there are only non-fire
points faulted. However, the UL required
prevention of alarm memory erasure while there
are fire points faulted is still enforced. If an area
has faulted fire and non-fire points, then the alarm
memory is locked until the fire points are
returned to normal.
Changes made to the enhanced communication
path acknowledgement wait time do not allow the
no-ack-required option when anti-replay is
enabled for the same path. When
Replay
is set to Yes and
Time
with is set to 0, the zero value is treated as if
it were the minimum setting of 5 seconds by the
control panel.
Changes made allow the Manual Idle Text
Forward Scroll to show faulted points when you
CC# Scroll Lock
set
condition occurs.
Changes made allow the View Area Status display
on the D1260 and D1260B Keypads to show the
default Area Arm Status text.