With a v7.06 or earlier D7212GV2 control panel,
if a network interface module (NIM) is
programmed as a Primary Device in any Route
Group, follow these programming rules:
-
Assign Enhanced Communication Path 1 as
the Primary Device in Route Group 1.
-
Assign Enhanced Communication Path 2 as
the Primary Device in Route Group 2.
Assign Enhanced Communication Path 3 as
-
the Primary Device in Route Group 3.
Assign Enhanced Communication Path 4 as
-
the Primary Device in Route Group 4.
When all areas associated with an account are
armed, the keypads in those areas display the text
programmed in the
The control panel is supposed to provide a way to
alternately use the display text programmed in the
Area # is On
prompt under the same conditions,
but this feature is not yet available.
When an invisible point is programmed with
P# RlyResp Type
relay must be manually reset using keypad
[COMMAND 54]. Only visible points allow their
associated relay to reset when the alarm memory
is cleared with this setting.
When the control panel is upgraded from V7.06
and earlier to V7.07 and later, the
Display
prompt defaults to 150 sec instead of to
the intended factory default of 60 sec.
The Easy Exit feature was disabled in firmware
version 7.07 to address the issues described in
the GV2 Arming Without Passcode Technical Service
Note (P/N: F01U077005).
© 2007 Bosch Security Systems, Inc.
130 Perinton Parkway, Fairport, NY 14450-9199 USA
(800) 289-0096
Area # Acct Is On
prompt.
set to 2 (Relay Latches), the
AC Fail
F01U009079-04
Release Notes for Version 7.07
12/07
D7212GV2