About Output Device Programming (*79/*80 Menu Mode); *79 Menu Mode: Output Device Mapping - Honeywell Ademco Vista-12D Installation And Setup Manual

Table of Contents

Advertisement

About Output Device Programming (*79/*80 Menu Mode)

Output Devices: The system supports up to 4 relays and/or Powerline Carrier devices (X-
10 devices) plus 2 built-in trigger outputs in any combination. These 6
"outputs" are assigned to system-wide output numbers (01-06 and 17-18).
Use *79 Menu Mode to assign output numbers and map them to device
addresses.
Output Functions: The system also provides up to 12 installer-defined output functions,
which can be assigned to any of the physical outputs. Therefore, the action
of any one of the outputs can be based on as many of these functions as
desired. This lets a single relay or X-10 device perform many functions.
Use *80 Menu Mode to define output functions.
NOTE: When navigating the *79 and *80 menus: The [
advance to the next prompt. The [#] key is used to revert back to the last question to check or
change an entry. Press [
Output Device programming involves:
1. Use *79 Menu Mode to assign module and output numbers and map them to device
addresses.
NOTE: You must map output devices using *79 Menu Mode before you can use *80
Menu Mode.
2. Use *80 Menu Mode to create output definitions, which control the output devices.

*79 Menu Mode: Output Device Mapping

Use this menu to assign Relay Module device addresses and specific relay numbers, and
Powerline Carrier unit numbers. The system is based on predefined module addresses for 4204
and 4229 modules. Refer to the table shown at the "Module Address" prompt on the next page
and set the modules' addresses (via module DIP switches) accordingly.
The following table shows how these outputs are identified.
Output Identification
This output...
Relays:
X-10 Device
Built-in Outputs
] to go forward again.
is identified by...
the Relay Module's device address and the relay position on that module (i.e. the
physical relay number, 1-4, on that module).
a house ID (entered in data field *27) and the unit number of the device.
the output number assigned, 17 for trigger 1 and/or 18 for trigger 2.
Menu Mode Programming
] key is used to accept an entry and
5-13