FIELD
TITLE and DATA ENTRIES
*88
Exit Options
0 = all intrusion zones must be intact before
arming
1 = All intrusion zones except in exit path
(zone list 12) must be intact before
arming. Will go into alarm if not restored
at end of exit time
2 = All intrusion zones except in exit path
(zone list 12) must be intact before
arming. Will be bypassed if not restored
at end of exit time
3 = Final contact set: All intrusion zones
except in exit path (zone list 12) must
be intact before arming. Once armed,
exit delay remains on indefinitely until
the last zone, as defined in zone list 8,
is restored; then there is 5-second exit
delay before arming state is active
Event Log Full Report Code
*89
0 = disable; 1-F = see description above ∗59
Event Log Enables
*90
0 = no event logging
1 = log Alarm/Alarm Restore
2 = log Trouble/Trouble Restore
4 = log Bypass/Bypass Restore
8 = log Open/Close
x = log combination of events (add value of
entries)
Data Field Programming
EXPLANATION
Select the desired option.
NOTE: Must be "0" if system uses zone type 82 -
blockschloss.
If an Event Logging selection is made in field ∗90, a
message can be sent to the central station receiver
when the log is 80% full. If the log becomes full, new
messages overwrite the oldest messages in the log.
This system has the ability to record up to 254 events
in a history log. At any time, the downloader operator
can then upload the log and view or print out all or
selected categories of the log. The downloader operator
can also clear the log. Event log can also be viewed at
an alpha keypad (see User Guide for log display
format).
The display/printout at the central station will show
the date, time, event, and description of the
occurrences.
Data Entry Example: To select Alarm/Alarm Restore"
and "Open/Close", enter 9 (1+ 8); to select all events,
enter #15.
4-11