On-Board Triggers - Honeywell Ademco Vista-12D Installation And Setup Manual

Table of Contents

Advertisement

On-Board Triggers

Connect field wiring to the desired trigger pin
on the 8-pin trigger connector centrally located
above the terminal strip.
• If using a Powerline Interface Modulator and
powerline carrier devices, use the
SA4120XM-1 cable (part of 4120TR Trigger
Cable). See previous Powerline Carrier
Device section.
• If only using the on-board triggers, you can
use a 4-wire cable (N4632-4, supplied with
the control) as shown below.
8-PIN TRIGGER CONNECTOR
1
3
4
5
Figure 11. On-Board Trigger Connector with
SA4120XM-1 Cable for Use With X10 Powerline
Interface Modulator
8-PIN TRIGGER CONNECTOR
1
3
Figure 12. On-Board Trigger Connector with
4-Wire Cable for Trigger Use Only
6
7
8
SA412OXM-1
CABLE
00-trigcon-003-V1
4
5
6
7
8
4-WIRE
CABLE
00-trigcon-005-V2
Mounting and Wiring the Control
Notes
• There are two on-board triggers that can
be used to activate output devices.
• These outputs are normally high, and go
low upon programmed condition.
• The outputs can be programmed for
inverted operation (normally low, go high)
using *79 Menu mode.
• Program these triggers using *80/*81
Menu modes as you would for any other
relay output.
• When using these outputs, note:
pin 1 = output number 17 (trigger 1):
15 ohms to ground when closed
(output low), open when off
(output high, normal default); can
be used to reset smoke detector
power (must set "output normal
low = yes" in *79 Menu mode, and
set for zone type 54, fire zone
reset, in *80 Menu mode); or can
support 12V relay module that
draws less than 100mA
pin 5 = output number 18 (trigger 2):
15 ohms to ground when closed
(output low); open when off
(output high, normal default); or
can support 12V relay module
that draws less than 20mA.
• NOTE: Do not exceed 120mA combined
current for both triggers. Doing so
can damage PC board components
and will void the system's
warranty.