DKS 6003 Installation & Owner's Manual

Hide thumbs Also See for 6003:

Advertisement

Installation/Owner's Manual
Use this manual for circuit board 4302-010 Revision A or higher.
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
UL 325 Compliant
Vehicular Swing Gate Operator
S t a
n d
C o
n t r
B o
x
Circuit Board
Serial Number
and Revision Letter:
Copyright 2010 DoorKing, Inc. All rights reserved.
D e
l u x
a r d
C o
n t r
o l
G
I N
R N
B o
W A
x
U S
E
C A
H
A T
N
C A
D E
T E
O R
t
si gh
G A
R Y
in
G
J U
is
V IN
ar ea
.
IN
ns
M O
U S
n ga
te
ct io
st ru
ar ea
R IO
w he
d ob
te
S E
ly
ga
on
an
in
te
le
pl ay
ra te
ga
pe
op
to
h
of
re n
ro
ug
O pe
k th
d fr
ee
ild
w al
ch
.
an
lo w
te .
or
ns
t al
th
ct io
e ga
pa
ru
D o
no
er at
te
in g.
in st
ga
m ov
fe ty
op
d in
or
is
d sa
t st
an
te
ga
l an
D o
no
le
ua
w hi
m an
th
r' s
pa
ne
d ow
R ea
2
38
53
T O
M S
O R
5
-3 2
N F
U L
C O
S I/
4 7
O R
A N
T O
. 2
D
A T
IF IE
N O
E R
R T
O P
2 .2
C E
C 2
T E
S A
G A
H P
N /C
C A
A R
U L
H IC
V E
S
A S
C L
E
D E
L
A S
P H
M O
R IA
L
H z
6 0
S E
S
LT
V O
C A
D
d ,
P S
O A
o o
E L
le w
A M
In g
A T
X G
c. ,
M A
, In
in g
o rK
D o
Copyright 2009 DoorKing, Inc. All rights reserved.
6003
6003
6003
6003-065-J-7-10
e
o l
G
I N
R N
W A
E
U S
C A
H
A T
N
D E
C A
O R
T E
t
G A
R Y
si gh
in
G
J U
is
ar ea
V IN
IN
ns
.
U S
te
ct io
M O
n ga
ar ea
st ru
R IO
w he
d ob
te
S E
ly
ga
on
an
in
te
le
pl ay
ga
op
h
ra te
pe
to
ug
of
re n
k th
ro
O pe
ee
ild
d fr
ch
w al
.
an
lo w
or
ns
t al
te .
ct io
e ga
pa
th
ru
no
te
in g.
in st
D o
er at
ga
op
d in
m ov
fe ty
or
is
d sa
an
te
t st
ga
l an
no
le
ua
D o
w hi
m an
pa
th
r' s
ne
d ow
R ea
38
2
53
T O
M S
5
O R
-3 2
N F
U L
C O
S I/
A N
T O
4 7
O R
D
. 2
A T
IF IE
N O
E R
R T
2 .2
O P
C E
C 2
T E
S A
G A
N /C
H P
A R
C A
U L
H IC
V E
S
A S
C L
E
L
A S
D E
P H
M O
L
H z
R IA
S E
6 0
S
LT
V O
C A
d ,
O A
D
o o
P S
le w
A M
E L
A T
In g
X G
c. ,
M A
, In
in g
o rK
D o
TM

Advertisement

Table of Contents
loading

Summary of Contents for DKS 6003

  • Page 1 6003 6003 6003 Installation/Owner’s Manual Vehicular Swing Gate Operator Use this manual for circuit board 4302-010 Revision A or higher. 6003-065-J-7-10 S t a l u x a r d n t r n t r si gh V IN...
  • Page 3: Specifications

    6003 SPECIFICATIONS Class of Operation Model 6003 - UL325 Class I Type of Gate Residential Vehicular Swing Gates Only Motor RPM 1400 Maximum Thrust 300 daN Voltage / Phase 115 VAC Single Phase Input Power – 24 VDC Operating Power...
  • Page 4: Control Boxes Specifications

    CONTROL BOXES SPECIFICATIONS Class of Operation Models 6002, 6003, 6004 and 6400 - UL325 Class I Type of Gate Residential Vehicular Swing Gates Only Voltage / Phase 115 VAC 60 Hz Single Phase Input Power – 24 VDC Operating Power Back-Up Power 24 VDC battery power during power outages.
  • Page 5: Table Of Contents

    3.3 Limit Sensor Adjustments 3.4 Inherent Entrapment Sensing Adjustment 3.5 Shutdown Conditions 25-26 Soft Shutdown Hard Shutdown SECTION 4 - MAINTENANCE AND TROUBLESHOOTING 4.1 Maintenance 4.2 Diagnostics Check 27-28 4.3 Troubleshooting 28-29 4.4 Accessories 6003 with Standard or Deluxe Control Box Schematics 6003-065-J-7-10...
  • Page 6: Astm F2200 Standard For Gate Construction

    2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving in the opening direction. 3. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exist, such as the perimeter reachable by a moving gate or barrier. 6003-065-J-7-10...
  • Page 7: Important Notices

    Do not allow children to play in the area of the operator or to play with any gate-operating device. • To remove the gate operator from service, operate the gate to the full open position and then shut off power to the operator at the service panel. 6003-065-J-7-10...
  • Page 8: Ul 325 Entrapment Protection

    C - Inherent adjustable clutch or pressure relief device. D - Provision for connection of, or supplied with, an actuating device requiring continuous pressure to maintain opening or closing motion of the gate. E - An inherent audio alarm. 6003-065-J-7-10...
  • Page 9: Glossary

    ENTRAPMENT - The condition when an object is caught or held in a position that increases the risk of injury. 6003-065-J-7-10...
  • Page 10: Swing Gate Requirements

    If space is less than 16 inches, entrapment protection in this area is required. ASTM F2200 7.1.1.1 and 7.1.1.2 Not Allowed Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches. ASTM F2200 4.3 6003-065-J-7-10...
  • Page 11: Swing Gate Protection

    Number and placement of loops is dependent on the application. Separate Pedestrian Walkway Located so pedestrians cannot come in contact with the vehicular gate. Automatic Exit Loop (Optional) will provide an open command to the gate operator(s) when a vehicle is exiting the property. 6003-065-J-7-10...
  • Page 12: Section 1 - Installation

    The actuator arm can be manually operated in case of power failure. Never manually release the arm until you have verified that ALL power has been shut-off to it (Including batteries). Powered Shaft Manually key release the actuator. Powered shaft can be pulled out. 6003-065-J-7-10...
  • Page 13: Gate "Opens To The Inside" Installation

    Actuator arm MUST be level! Middle Bottom Installation Note: Make sure that the operator is mounted high enough off the ground that it will NOT come in contact with standing or Bottom flowing water. This will Gate in Closed Position damage the operator. 6003-065-J-7-10...
  • Page 14: Gate "Opens To The Outside" Installation

    Actuator arm MUST be level! Bottom Installation Note: Make sure that the operator is Middle mounted high enough off the ground that it will NOT come in contact with standing or flowing water. This will Bottom damage the Gate in Closed Position operator. 6003-065-J-7-10...
  • Page 15: Mounting Actuator Arm

    If brackets are going to be welded to the gate and/or wall, only tack weld the brackets with the arm attached. Protect the arm from welding sparks during tack welding. Remove arm before completely welding around the brackets. Make sure the brackets are level when tack welding them! The arm will not operate properly if not level. 6003-065-J-7-10...
  • Page 16: Mounting Control Box With Conduit And Warning Signs

    Permanently install the supplied warning signs in locations so that the signs are visible by persons on both sides of the gate. • Use appropriate hardware such as wood or sheet metal screws (not supplied) to install the warning signs. 6003-065-J-7-10...
  • Page 17: Section 2 - Wiring

    Not Used Primary Actuator ONLY 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Secondary Actuator Cable Primary Actuator Cable DoorKing interconnection cable (P/N 2600-75x) inside underground conduit (Sold separately) 6003-065-J-7-10...
  • Page 18: Secondary Entrapment Protection Wiring

    Terminal for the secondary entrapment device input. COMMON Secondary Entrapment Protection Terminal Photo Sensors Closed Gates Safety Protection Safety Protection 4302 2 3 4 5 6 7 10 11 12 13 14 15 16 17 18 19 20 SW 1 Switch 5 OFF 6003-065-J-7-10...
  • Page 19: Main Terminal Description

    When gate is closing, input has no becomes the output from a plug-in loop affect on the gate operator if SW 1, detector installed in the EXIT loop port SW 1 switch 5 is ON (set for shadow input). SW 1 of the circuit board. 6003-065-J-7-10...
  • Page 20: Main Terminal Wiring

    1000 feet. (Dry contact) All control device inputs to the terminal strip must be NORMALLY N.O. OPEN. SW 1 SW 1 N.O. Note: Telephone entry device must use a separate power Key Switch (Dry contact) source. 6003-065-J-7-10...
  • Page 21: Loop Detector Wiring

    SW 2, switch 1 wires are twisted 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19 20 is ON and approx. 6 twists switch 2 is OFF. per foot. SW 2 6003-065-J-7-10...
  • Page 22: High Voltage Wiring And Battery Connection

    AND the battery plug must be disconnected Wire Size Distance from the circuit board. 14 AWG Up to 200 ft Greater than 12 AWG 200 ft It is recommended that a surge suppressor be installed on the high voltage power lines. 6003-065-J-7-10...
  • Page 23: Section 3 - Adjustments

    Dry relay contacts (terminals 10-11) can SECONDARY (dual) operators. be set for Normally Open (NO) or See 3.4 on page 24. Primary Normally Closed (NC) operation by placing the relay shorting bar on the N.O. Min Max or N.C. pins respectively. Sensitivity 6003-065-J-7-10...
  • Page 24: Dip-Switch Descriptions And Functions

    This feature is useful when a magnetic lock is used to secure the gates. SW 1-Switch 7 Sets up the circuit board for single or dual (Primary / Secondary) gate operation. Spare switch. Leave in the OFF position. SW 1-Switch 8 6003-065-J-7-10...
  • Page 25: Limit Sensor Adjustments

    Repeat if necessary. L i m i t A s s e Re-install the limit cover. Adjust the secondary actuator limit sensors if dual actuators have been installed. 6003-065-J-7-10...
  • Page 26: Inherent Entrapment Sensing Adjustment

    Place an immobile object along the gate path, allowing the gate to strike it while in the open or close cycle. The gate must reverse direction after striking the object. If it does not, increase the reverse sensitivity (step ) and repeat this test until the correct sensitivity has been set for the open and close directions. 6003-065-J-7-10...
  • Page 27: Shutdown Conditions

    Activating any of these inputs will reset the gate. At that point the gate will return to normal operation. If the gate is open, the automatic close timer will then time out and close the gate. Continued on next page. 6003-065-J-7-10...
  • Page 28: Hard Shutdown

    This includes activation of a key switch or open command and activation of the automatic exit loop (If used). Activation of a close command will run the gate to the closed position. 6003-065-J-7-10...
  • Page 29: Section 4 - Maintenance And Troubleshooting

    Pull the loop detector circuit boards from the loop ports on the operator circuit board. If the malfunction persists, the problem is not with the loop system. For more information refer to the loop detector instruction sheet and the DoorKing Loop and Loop Detector Information Manual. Continued on next page. 6003-065-J-7-10...
  • Page 30: Troubleshooting

    1 to the input terminal being checked. If LED lights and gate opens, problem is with the keying device. If LED does not light, replace control board. • Check motor as described above “Operator(s) will not run. Power LED is ON”. 6003-065-J-7-10...
  • Page 31: Accessories

    Operator will not run. 4.4 Accessory Items The following accessory items are available for the model 6003 swing gate operator. Photo Sensor - Non-contact sensors (photo-cells) for use as a secondary entrapment protection device. EMX Industries, Inc. Model IRB-325 MMTC, Inc.
  • Page 32: 6003 With Standard Or Deluxe Control Box Schematics

    6003 with Standard or Deluxe Control Box Schematics Brown 1 Blue 2 Orange 3 Motor Motor Red 4 Yellow 5 Green 6 Green/Yellow 7 Secondary Black 1 2 3 4 5 6 7 1 2 3 4 5 6 7...
  • Page 33 6003-065-J-7-10...
  • Page 34: 6003-065

    6003 6003 6003 Installation/Owner’s Manual Vehicular Swing Gate Operator Use this manual for circuit board 4302-010 Revision A or higher. 6003-065-J-7-10 www.doorking.com DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 Copyright 2009 DoorKing, Inc. All rights reserved.

Table of Contents