Ac powered vehicular swing gate operator (44 pages)
Summary of Contents for DKS 6003
Page 1
Actuator Arm and 6003 6003 6003 Control Box Mounting Vehicular Swing Gate Operator To wire this operator and complete the installation, refer to a specific control box “Wiring/Owner’s manual”. 6003-065-T-3-16 EXTERNAL ENTRAPMENT PROTECTION MUST be installed or the gate operator WILL NOT function.
6003 SPECIFICATIONS Class of Operation Model 6003 - UL 325 Class I Type of Gate Vehicular Swing Gates Only Actuator Arm Voltage 24 VDC Current 3 Amps Motor RPM 1400 Maximum Thrust 300 daN Max Gate Weight 300 Lbs. Max Gate Length...
Gate “Opens to the Inside” Installation Gate “Opens to the Outside” Installation Mounting Actuator Arm Mounting Control Box with Conduit 13-14 Install Warning Signs In-Ground Loops Entrapment Protection Positions “Opens to the Inside” Accessory Items 6003 Primary/Secondary 4302 Circuit Board Connection 6003-065-T-3-16...
2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving in the opening direction. 3. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exist, such as the perimeter reachable by a moving gate or barrier. 6003-065-T-3-16...
Do not allow children to play in the area of the operator or to play with any gate-operating device. • To remove the gate operator from service, operate the gate to the full open position and then shut off power to the operator at the service panel. 6003-065-T-3-16...
Type C - Inherent force limiting, inherent adjustable clutch or inherent pressure relief device. Type D - Actuating device requiring constant pressure to maintain opening or closing motion of the gate. * B1 and B2 means of entrapment protection must be MONITORED. 6003-065-T-3-16...
NOT required for this area. If distance is less than 16 inches, entrapment protection in this area is required. ASTM F2200 7.1.1.2 Not Allowed Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches. ASTM F2200 4.3 6003-065-T-3-16...
Number and placement of loops is Monitored device dependent on the application. helps protect against entrapment when needed. Automatic Exit Loop (Optional) will provide an open command to the gate operator(s) when a vehicle is exiting the REQUIRED property. for operator to function. 6003-065-T-3-16...
Placing hinges close to the corner can eliminate a potential entrapment area (See Swing Gate Requirements on page 7). Manual Key Release Powered Shaft Manually key release the actuator. Powered shaft can be pulled out. 6003-065-T-3-16...
Actuator arm MUST be level! Middle Bottom Installation Note: Make sure that the operator is mounted high enough off the ground that it will NOT come in contact with standing or Bottom flowing water. This will Gate in Closed Position damage the operator. 6003-065-T-3-16...
Actuator arm MUST be level! Bottom Installation Note: Make sure that the operator is Middle mounted high enough off the ground that it will NOT come in contact with standing or flowing water. This will Bottom damage the Gate in Closed Position operator. 6003-065-T-3-16...
If brackets are going to be welded to the gate and/or wall, only tack weld the brackets with the arm attached. Protect the arm from welding sparks during tack welding. Remove arm before completely welding around the brackets. Make sure the brackets are level when tack welding them! The arm will not operate properly if not level. 6003-065-T-3-16...
Page 16
Typical conduit To attach post to concrete, configuration DoorKing recommends four (4) 3/8” x 3” sleeve anchors (not supplied). (not supplied). Do Not mount post on asphalt. 6003-065-T-3-16...
Reverse loops work in conjunction with completely opened by the time the shadow loop and both should be used. is in or near the gate’s swing pathway. you drive up to it (Free exit). 6003-065-T-3-16...
MONITORED entrapment protection device is REQUIRED. Closing Gate Potential Entrapment Area: If the CLOSING gate could cause an entrapment, then installation of a MONITORED entrapment Monitored protection device is REQUIRED. Reversing Monitored Edge Potential Photo Sensor Entrapment Area 6003-065-T-3-16...
Accessory Items UL 325 Monitored Entrapment Protection Devices available for the model 6003 swing gate operator. Type B2 Contact Sensors (Reversing Edge) Miller Edge Sensing Edges - all models with a T2 (resistive) termination. Miller Edge Monitored Gate Link Model MGL-K20...
Actuator Arm and 6003 6003 6003 Control Box Mounting Vehicular Swing Gate Operator To wire this operator and complete the installation, refer to the specific control box “Wiring/Owner’s manual”. 6003-065-T-3-16 www.doorking.com DoorKing, Inc. 120 S. Glasgow Avenue Inglewood, California 90301 U.S.A.