HearthStone Champlain 8301 Owner's Manual page 15

Gas-fired direct vent heater
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc
screws, keeping the screws as close to the wall
thimble as possible.
strapping so the thimble cover will fit properly.
Screw the thimble cover to the wall.
The adjustment range for wall thickness for
this configuration is 3"min to 9"max.
II. F
V
IREPLACE
ENTING
-40' maximum system height (without offsets)
-14' maximum offset (refer to Figures 10 - 12)
-Maximum rise to run = 1 to 5 (refer to Figures 9-
13)
-The termination must meet the requirements
outlined in Figure 8 and Figure 9.
III. V
T
ERTICAL
ERMINATION
-40' maximum system height (without offsets)
Figure 11: Approved DV Vertical Co-Axial Termination Configurations
Bend or cut the excess
I
NSTALLATIONS
V
C
ENTING
ONFIGURATIONS
Figure 10: Vertical Venting Rules
CHAMPLAIN DV Model 8301