F2 Input And Output Terminal Function Parameters - Fuling Inverter DZB200 Series User Manual

Dzb300 series high-performance general-purpose inverter, open-loop vector control inverter
Hide thumbs Also See for DZB200 Series:
Table of Contents

Advertisement

DZB0 Series
Function
Name
Code
Mutual inductance of
F1.09
0.1 6553.5mH
motor sta tor/rotor
F1.10
No -l oad c urrent
0.01 655.35A
0 NO operation
Self-learnin g of
:comp lete tunin g
motor par ameters
1
F1.11
(Invalid for DZB200)
2:sta tic tu ning Se lf-learnin g
Spee d loo p pr op or tional
F1.12
0 100
ga in1
F1.13
Spee d loo p integral time1
0.01 10.00s
Switching lo w
F1.14
0.00Hz F1.1 7
po int frequenc y
Spee d loo p pr op or tional
F1.15
0 100
ga in 2
Spee d loo p integral
F1.16
0.01 10.00s
tim e 2
Switching high
F1.17
F1.14 F0.04
po int frequenc y
VC slip compensating
F1.18
50% 200%
factor
0.0
200.0%(inver ter rated current)
F1.19
Up per torque limit setting
0 Lin ear V/F curve
V/F cur ve setting
F1.20
1 square tor qu e V/F c urve
F1.21
Torque boost
0.0% (auto)
0.0% 50.0% (relative to motor
F1.22
Torque boost cut-o ff
rated frequency)
F1.23
V/F slip compensation limit 0.0 200.0%
0:No Operation
Energy Con se rv ati on
F1.24
Sele cti on
1:Energy Conservation
F2 Input and Output Terminal Function Parame ters
On-off sig na l filte r tim es
F2.00
1 10
S1 Terminal Function
0:No Function
F2.01
Sele cti on
1:Forward
S2 Terminal Function
F2.02
2:Reverse
Sele cti on
S3 Terminal Function
3:th ree-wir e c ontrol
F2.03
Sele cti on
4:Forward Jo gging
S4 Terminal Function
F2.04
5:Rever se Jogging
Sele cti on
- 25-
Chapter 5 Function Parameters List
Default
Modifi
Serial
Setting Range
Value
cation
No
Set by
35.
model
Set by
36.
model
Self-learning
0
37.
38.
30
0.50s
39.
5.00Hz
40.
25
41.
1.0 0s
42.
10.00Hz
43.
100%
44.
150.0%
45.
0
46.
%~
0.1
30 .0
0
47.
20.0%
48.
100%
49.
0
**
50.
5
51.
1
52.
2
53.
4
54.
7
55.
DZB Series
Function
Name
Code
S5 Termi na l Function
6:Fr ee run stop
F2.05
Sele ction
7:Failure reset
S6 Termi na l Function
F2.0 6
8:External fault input
Sele ction
9:Fr eq uency setting(UP)
10:Fre quency setting(DOWN)
11:Frequency up/down setting
clear
12:Multi-Speed Terminal 1
13:Multi-Speed Terminal 2
14:Multi-Speed Terminal 3
15:ACCEL/DECEL Time selection
16:PID con trol pause
17:Tra ve rse pause at current
frequency
18:Tra ve rse res et
19:ACCEL/DECEL forbid
20 25:Reserved
0 two-wire con trol 1
1 two-wire con trol 2
Terminal control
F2.0 7
mode
2 three-wi re control 1
3 three-wi re control 2
UP/DOWN frequen cy
F2.08
0.01 50.00Hz/s
in crem en t v ariable rate
F2.0 9
0.00V 10.00V
VI lowe r limit
VI lowe r limit
F2.1 0
-100.0% 100.0%
correspond ing setting
VI upper limit
F2.11
0.00V 10.00V
VI upp er limit
F2.1 2
-100.0% 100.0%
correspond ing setting
F2.13
VI inpu t filtering time
0.00s 10.00s
F2.1 4
CI lo wer lim it
0.00V 10.00V
CI lo wer lim it
F2.15
-100.0% 100.0%
correspond ing setting
CIuppe r limit
F2.1 6
0.00V 10.00V
- 26-
Chapter 5 Function Parameters List
Default
Modifi
Serial
Setting Range
Value
cation
No
12
56.
13
57.
0
58.
0.50Hz/s
59.
0.0 0V
60.
0.0%
61.
10.00V
62.
100.0%
63.
0.10s
64.
0.0 0V
65.
0.0%
66.
10.00V
67.
www.yusto.ru
info@yusto.ru

Advertisement

Table of Contents
loading