Function
Name
Code

F0 Basic Function Parameters

0 Sp eed sensorl es s vector
control (S VC)
F0.00
Control mode
1 V/F c ontrol
0 Ke yb oard
Comman d source
F0.01
1 Term inal
selecti on
2 Communi ca tion
0 Valid , a nd in ve rter memorize
when power dow n
Keyboard a nd terminal
1 Valid , a nd in ve rter does not
F0.02
UP/DOWN setting
mem orize when power down
2 Invalid
0 Ke yb oard
1 VI
2 CI
Frequency command
F0.03
3 VI+ CI
Sele cti on
4: Multi-speed
5: PID control
6: Communic ation
F0.04
Maximum o utput freq uency 10.00 600.00Hz
Upper limit frequ ency
F0.05
F0.06 F0.04
Lower limit frequ ency
F0.06
0.00 Hz F0.05
Keyboard freq uency setting 0.00 Hz F0.04
F0.07
F0.08
ACCEL time 1
0.1 3600.0s
F0.09
DECEL time 1
0.1 3600.0s
0 Operati ng at default direction
Operation d irection
1 Operati ng at reverse directio n
F0.10
selecti on
2 NO invers e operating
Carrie r frequenc y setting
F0.11
1.0 15.0k Hz
0 NO ope ra tion
Functional parameters
F0.12
1 Restore default v alue
restoration
2 Del ete failure r ec ords
0 Inv ali d
F0.13
AVR sele cti on
1 Val id all the time
- 23-
Chapter 5 Function Parameters List
Default
Modifi
Serial
Setting Range
Value
cation
No
1
0.
0
1.
0
2.
0
3.
4.
50.00Hz
5.
50.00Hz
6.
0.00Hz
7.
50.00Hz
1 0.0s
8.
9.
1 0.0s
2
10.
Set by
11.
model
0
12.
1
13.
DZB Series
Function
Name
Code
2 Invalid durin g dece lerati on
0 Direct sta rt
1 DC brakin g first and then start
F0.1 4
Start Mod e
2 Runnin g speed pick-u p and
then start
Start fr eq uency
F0.15
0.00 10.00Hz
Ho ld time of start
F0.1 6
0.0 50.0s
frequ ency
Braking c urrent
F0.1 7
0.0 150.0%
be fore sta rting
Braking time
F0.18
0.0 50.0s
be fore sta rting
0 DECEL Stop
Stop Mode
F0.1 9
1 Free ru n Sto p
Begi nning Frequ en cy of
F0.2 0
0.00
F0.04
brak ing
F0.21
Waiting ti me o f b ra king
0.0 50.0s
DC b ra king curre nt
F0.2 2
0.0 150.0%
F0.23
DC b ra king tim e
0.0 50.0s
De ad time between
F0.2 4
0.0 3600.0s
forward a nd reverse
0 Term inal command in va lid
Terminal command
when power on
F0.25
prote ction when
1 Term inal command valid whe n
po wer on
po wer on

F1 Motor Parameters

0 B mode l
F1.0 0
Inverter model
1 P model
Motor rated po wer
F1.01
0.4 900.0kW
Motor rated frequenc y
F1.0 2
0.01Hz F0.04
Motor rated spee d
0 36000rpm
F1.03
Motor rated volta ge
F1.0 4
0 460V
F1.05
Motor rated current
0.1 1000.0A
F1.0 6
Motor sta tor resistance
0.001 65.535
F1.0 7
Motor rotor res istan ce
0.001 65.5 35
Motor stator/ro tor
F1.08
0.1 65 53.5 mH
induc tance
- 24-
Chapter 5 Function Parameters List
Default
Modifi
Serial
Setting Range
Value
cation
No
0
14.
0.5 0Hz
15.
0.0s
16.
0.0%
17.
0.0s
18.
0
19.
0.0 0Hz
20.
0.0s
21.
0.0%
22.
0.0s
23.
0.0s
24.
0 1
25.
Set by
26.
mode l
Set by
27.
mode l
50.00Hz
28.
Set by
29.
mode l
Set by
30.
mode l
Set by
31.
mode l
Set by
Ω
32.
mode l
Set by
Ω
33.
mode l
Set by
34.
mode l
www.yusto.ru