F2 Input And Output Terminal Function Parameters - Fuling Inverter DZB200 Series User Manual

High-performance general-purpose inverter. open-loop vector control inverter
Hide thumbs Also See for DZB200 Series:
Table of Contents

Advertisement

 DZB0 Series
5 / 1 4 / 2 0 1 8
Function
Name
Code
Mutual inductance of
F1.09
motor stator/rotor
F1.10
No-load current
Self-learning of
motor parameters
F1.11
(Invalid for DZB200)
Speed loop proportional
F1.12
gain1
Speed loop integral time1
F1.13
Switching low
F1.14
point frequency
F1.15
Speed loop proportional
gain 2
Speed loop integral
F1.16
time 2
Switching high
F1.17
point frequency
VC slip compensating
F1.18
factor
Upper torque limit setting
F1.19
F1.20
V/F curve setting
Torque boost
F1.21
F1.22
Torque bo ost cut-off
F1.23
V/F slip compensation limit 0 . 0 2 0 0. 0%
Energy Conservation
F1.24
Selection

F2 Input and Output Terminal Function Parameters

On-off signal filter times
F2.00
S1 Terminal Function
F2.01
Selection
S2 Terminal Function
F2.02
Selection
S3 Terminal Function
F2.03
Selection
S4 Terminal Function
F2.04
Selection
 
h t t p : / / s l i d e p d f . c o m / r e a d e r / f u l l / f u l i n g - i n v e r t e r - u s e r - m a n u a l
Chapter 5 Function Parameters List
Default
Setting Range
Value
Set by
0. 1 6553. 5mH
model
Set by
0. 01
655. 35A
model
0 NO operat ion
1
: complete tuning
Self-learning
0
2 : static tuning Self-learning
0 1 00
30
0. 01
10.00s
0.50s
0. 00Hz F1.1 7
5.00Hz
0 1 00
25
0. 01
10.00s
1.0 0s
F1.14 F0. 04
10.00Hz
5 0 % 2 0 0%
100%
0.0
200.0%(inverter rated current)
150.0%
0 Linear V/F curve
0
1 square torque V/F curve
0. 0% (auto)
%~
0.1
30 .0
0
0.0% 50.0% (relati v e to motor
20.0%
rated frequency)
100%
0:No Operation
0
1:Energy Conservation
1 10
5
0:No Function
1
1:Forward
2
2:Reverse
3:three-wire control
4
4:Forward Jogging
7
5:Reverse Jogging
- 2 5 -
 DZB Series
F u l i n g I n v e r t e r U s e r M a n u a l - s l i d e p d f . c o m
Function
Modifi
Serial
cation
No
Code
35 .
F2.05
36 .
F2.0 6
37 .
38 .
39 .
40.
41.
42.
43.
44.
45.
46.
F2.07
47.
48 .
F2.08
49 .
F2.09
**
50 .
F2.10
F2.11
51.
F2.12
52 .
F2.13
F2.14
53 .
F2.15
54 .
F2.16
55.
Name
Setting Range
S5 Terminal F unction
6:Free run stop
Selection
7:Failure reset
S6 Terminal F unction
Selection
8:External fault input
9:Frequency setting(UP)
10:Frequency setting(DOWN)
11:Frequency up/down setting
clear
12:Multi-Speed Terminal 1
13:Multi-Speed Terminal 2
14:Multi-Speed Terminal 3
15:ACCEL/DECEL Time selection
16:PID control pause
17:Traverse pause at current
frequency
18:Traverse reset
19:ACCEL/DECEL forbid
20 25: Res er ved
0
two-wire control 1
1
two-wire control 2
Terminal control
mode
2
three-wire control 1
3
three-wire control 2
UP/DOWN frequency
0. 01 50. 00Hz /s
increment variable rate
0. 00V 10. 00V
VI lower limit
VI lower limit
- 100. 0% 100.0%
corresponding setting
VI upper limit
0. 00V 10. 00V
VI upper limit
- 100. 0% 100.0%
corresponding setting
VI input filtering time
0. 00s 10. 00s
CI lower limit
0. 00V 10. 00V
CI lower limit
- 100. 0% 100.0%
corresponding setting
CIupper limit
0. 00V 10. 00V
- 2 6 -
Chapter 5 Function Parameters List
Default
Modifi
Serial
Value
cation
No
12
56 .
13
57 .
0
58.
0.50Hz/s
59.
0.00V
60 .
0.0%
61 .
10.00V
62.
100.0%
63 .
0.10s
64.
0.0 0V
65.
0.0%
66.
10.00V
67.
1 6 / 5 4