Fuling Inverter DZB200 Series User Manual page 24

Dzb300 series high-performance general-purpose inverter, open-loop vector control inverter
Hide thumbs Also See for DZB200 Series:
Table of Contents

Advertisement

DZB Series
O u tp u t F r e q u e n c y f
O u tp u t
V o lta g e
D C B r a k e
w h e n
s ta r t in g
Fig. 6-3 DC Bra ke Diagram
Functio n
Name
Cod e
Dead time between
F0.2 4
0.0 36 00.0s
forward a nd reverse
It is to set the transient time during w hich the output frequency is 0 in the FWD /REV transi ent process
of inverter.
It is shown as following figure:
Output
Frequency f
Forward
Dead Time
Fig. 6-4 FWD/REV Dead Time Diagram
Functio n
Name
Cod e
0 Te rmin al comma nd in va lid
Terminal command
when power on
protection when
F0.25
1 Te rmin al comma nd vali d whe n
power on
po wer on
If operating command channel is set to terminal control, system will detect terminal status
automatically during inverter power on.
- 41-
Chapter 6 Parameter Description
T im e t
D C B ra k e
T im e t
w h e n
s to p p in g
Default
Setting Range
Value
0.0s
Time t
Reverse
Default
Setting Range
Value
0 1
DZB Series
0: Terminal command invalid when power on. Inverter will not run if it detect operating command terminal
is valid. When the operat ing command terminal is invalid and enable this terminal again, inverter will run.
1: Terminal command valid when power on. Inverter will startup automatically a fter initialization is
finished if it detect operation command terminal is valid.
Note: Customer shou ld be careful when you select this function, it may cause severe consequence.
F1 Motor Parameters
Function
Name
Code
0 B model
F1.00
Inverter model
1 P mod el
0: suit able for constant torque load of designated nominal parameter.
1: suit able for variable torque load (such as fan and pump).
Constant torque(B model) inverter can drive larger variable torque(P model) load directly.
'
'
For example,
DZB300B0220L4
inverte r is set 22KW B model as default, if you want to drive 30KW
fan, you should
Set F1.00 as 1
Set F1 group motor parameter again
Function
Name
Code
Motor rated power
F1.0 1
0.4 900.0kW
F1.02
Motor rated frequency
0.01Hz F0 .04
0 360 00rpm
F1.03
Motor rated speed
F1.04
Motor rated voltage
0 460 V
Motor rated current
F1.0 5
0.1 1000.0 A
Note: please set th ese codes according to motor n ameplate parameters. The superior performances
of vector control require precise motor parameters.
DZB series invert er provides para meter self-learning function. A ccurate paramet er self-learning comes
from correct setting of motor nameplate parameters.
In order to ensure the control performances, please do the motor setting based on the inverter standard
adaptive motor. If the motor rated power has a too big difference to the standard adaptive motor, the inverter
control performances will be deteriorated distinctly.
Note: resetting of motor rated power (F1.01) can initialize motor parameter F1.02-F1.10.
- 42-
Chapter 6 Parameter Description
Default
Setting Range
Value
Set by
model
Default
Setting Range
Value
Set by
model
50.00Hz
Set by
model
Set by
model
Set by
model