DZB Series
5 / 1 4 / 2 0 1 8
Function
Name
Code
F0 Basic Function Parameters
F0. 00
Cont r ol mode
Command source
F0.01
selection
Keyboard and terminal
F0.02
UP/DOWN setting
Frequency command
F0.03
Selection
Maximum output frequency 10. 00
F0.04
Upper limit frequency
F0.05
F0.06
Lower limit frequency
Keyboard frequency setting 0. 00 Hz F0. 04
F0.07
F0.08
ACCEL time 1
F0.09
DECEL time 1
F0.10
Operation direction
selection
Carrier frequency setting
F0.11
Functional parameters
F0.12
restoration
F0.13
AVR selection
h t t p : / / s l i d e p d f . c o m / r e a d e r / f u l l / f u l i n g - i n v e r t e r - u s e r - m a n u a l
Chapter 5 Function Parameters List
Default
Setting Range
Value
0
:
Speed sensorless vector
control (SVC)
1
:
1
V/ F c ontr ol
0
:
K e yb o ar d
:
1
Ter minal
0
2
:
Communi c ati on
0
:
Valid, and inverter memorize
when power down
1
:
Valid, and inverter does not
0
memorize when power down
2
:
I nv al id
0
:
K e yb o ar d
1
:
VI
2
:
CI
3
:
V I+ C I
0
4: Multi-speed
5: PID control
6: Communication
~
600.00Hz
50.00Hz
~
F0.06 F0. 04
50.00Hz
0. 00 Hz F0. 05
~
0.00Hz
~
50.00Hz
0.1
~
3600. 0s
10.0s
0. 1 3600. 0s
~
10.0s
0
:
Operating at default direction
1
:
Operating at reverse direction
2
2
:
NO inverse operating
Set by
~
1. 0 15. 0k Hz
model
:
0
NO operat ion
1
:
Restore default value
0
2
:
Delete failure records
0
:
I nv a li d
1
1
:
Valid all the time
- 2 3 -
DZB Series
F u l i n g I n v e r t e r U s e r M a n u a l - s l i d e p d f . c o m
Function
Modifi
Serial
cation
No
Code
●
0.
F0.14
●
1.
F0.15
F0.16
F0.17
※
2.
F0.18
F0.19
F0.20
※
3.
F0.21
F0.22
F0.23
F0.24
●
4.
5.
※
F0.25
※
6.
※
7.
※
8.
※
9.
F1.00
F1.01
●
10 .
F1.02
F1.03
※
11.
F1.04
F1.05
●
12 .
F1.06
F1.07
※
13 .
F1.08
Setting Range
Name
:
2
Invalid during deceleration
0
:
Di rec t s t art
Start Mode
1
:
DC braking first and then start
2
:
Running speed pick-up and
then start
Start frequency
~
0. 00 10. 00Hz
Hold time of start
~
0 .0
5 0 .0 s
frequency
Braking current
0 .0
~
1 5 0. 0 %
before starting
Braking time
0 .0
~
5 0 .0 s
before starting
:
0
DECEL St op
Stop Mode
1
:
Fr ee run St op
Beginning Frequency of
0 .0 0
~
F 0. 04
braking
Waiting time of braking
~
0 .0
5 0 .0 s
DC braking current
0 .0
~
1 5 0. 0 %
DC braking time
~
0 .0
5 0 .0 s
Dead time between
forward and reverse
0. 0 3600. 0s
~
:
0
Terminal command invalid
Terminal command
when power on
protection when
1
:
Terminal command valid when
power on
power on
F1 Motor Parameters
0
:
B m ode l
Inverter model
1
:
P m o de l
Motor rated power
~
0. 4 900.0k W
Motor rated frequency
~
0. 01Hz F0. 04
~
Motor rated speed
0
36000rpm
Motor rated voltage
~
0
46 0V
Motor rated current
~
0. 1 1000. 0A
Motor stator resistance
0. 001
~
65.535
Ω
Motor rotor resistance
0. 001
~
65.535
Ω
Motor stator/rotor
0. 1 6553. 5mH
~
inductance
- 2 4 -
Chapter 5 Function Parameters List
Default
Modifi
Serial
cation
No
Value
0
●
14 .
0.50Hz
※
15 .
0.0s
※
16 .
0.0%
※
17 .
0.0s
※
18 .
※
0
19 .
0.00Hz
※
20 .
0.0s
※
21 .
0.0%
※
22 .
0.0s
※
23 .
0.0s
※
24 .
0 1
~
※
25 .
Set by
●
26 .
model
Set by
●
27 .
model
50.00Hz
●
28 .
Set by
●
29 .
model
Set by
●
30 .
model
Set by
●
31 .
model
Set by
※
32 .
model
Set by
※
33 .
model
Set by
※
34 .
model
1 5 / 5 4