4.6.3.

Setting date display format

You can set the date display format to "DD MMM,'YY," "MMM DD,'YY," or "'YY-MMM-DD."
YY: Year MMM: Month DD: Day
Procedure
1.
Refer to "4.9.1 Changing to a maintenance mode" to display the maintenance menu.
2.
Press the
3.
Press the
DD MMM YY format
4.6.4.

Displaying as loran c time difference

The latitude and longitude can be displayed as RORAN C time difference.
Procedure
1.
Refer to "4.9.1 Changing to a maintenance mode" to display the maintenance menu.
2.
Press the
3.
Press the
4. Set the GRI, TD1, TD2, TD1 CORR and TD2 CORR.
4.6.5.

Setting transducer position of depth sounder (exclusive to JFE-380/680)

Select which transducer is used to display the measured water depth in the water depth value output
from depth sounder JFE-380/680.
This function is used to select the transducer position of the water depth value in the depth sounder
screen.
The transducer position that can be selected is Forward "FWD," Medium "MID," and Backward (AFT).
For detail screen, refer to page 2-3.
Procedure
1.
Refer to "4.9.1 Changing to a maintenance mode" to display the maintenance menu.
2.
Press the
3.
Press the
key to select "SYSTEM," "DATE DISP," and "TIME DISP" in order.
key to select the date display format, and press the
MMM DD YY format
key to select "SYSTEM," "LORAC C," "LORAN C" in order.
key to select "ON."
key to select "SYSTEM," "DEPTH," and "TRANS" in order.
key to enter the transducer position, and press the
key.
YY MMM DD format
key.