4.10. Setting Daisy Chain - JRC NWZ-4610 Instruction Manual

Multi information display
Hide thumbs Also See for NWZ-4610:
Table of Contents

Advertisement

4.10. Setting daisy chain

The power can be distributed to up to three units from one power supply by setting daisy chain.
The display units in the same dimmer group can share the dimmer.
Power is not supplied to the fourth and subsequent units.
ON: Power is supplied to the next MID for daisy-chaining.
OFF: Power is not supplied to the next MID.
When output a data by daisy chain, set the "DATA IN/OUT4".
Power supply
Power
CFQ-5766A
supply unit
Procedure
1.
Refer to "4.9.1 Changing to a maintenance mode" to display the maintenance menu.
2. Press the
key to select "DAISY CHAIN."
3. Press the
key to select ON/OFF, and press the
Caution
 Be aware that when the MID fails or the power is turned off if the power is supplied in
daisy-chain mode, power cannot be supplied to the subsequent MID.
 When the power is supplied in daisy-chain mode, the display unit closer to the power supply
starts to be activated, so it takes time for the second and subsequent display unit to be
activated.
 When the "DAISY CHAIN" is set to "ON", "DATA IN/OUT1" is set automatically to "SEND",
also "DATA IN/OUT3" is set automatically to "RECEIVE".
Although it can be switched over with manual, it recommends that reception connection from
an external unit uses "DATA IN/OUT3".
4-48
Power
supply
CFQ-5768
Power
supply
key.
Power cannot
be supplied

Hide quick links: