JRC NWZ-4610 Instruction Manual page 63

Multi information display
Hide thumbs Also See for NWZ-4610:
Table of Contents

Advertisement

4.9.5.2.
Setting reception
In the reception setting, set a bit rate.
There is no need to set a sentence or a cycle.
Procedure
1.
Refer to "4.9.1 Changing to a maintenance mode" to display the maintenance menu.
2.
Select "INTERFACE" and "DATA I/O" in this order by using
3.
Select a port and a format that are to be set by using
4.
Select "RECEIVE" from "DATA IN/OUT" by using
5.
Select "BIT RATE" by using
Available bit rates are "4800", "9600", "19200", and "38400".
Supplement
When the "SEND" or "RECEIVE" of data IN/OUT1 or data IN/OUT2 is set and one port is set,
the other port is also set concurrently. The message that is shown below is displayed to
prevent the unintentional setting of the other port. When setting a port, select "YES". If "NO"
is selected, the port is not set.
Setting port
Select an output format
.
.
Select RECEIVE
Select BIT RATE
.
.
4-41