4.9.14.

Demonstration

Through a demonstration, display and external output are enabled in the same way as the actual
equipment operation.
Procedure
1.
Refer to "4.9.1 Changing to a maintenance mode" to display the maintenance menu.
2.
Select "DEMO MODE" and "DEMO TYPE" in this order by using
3.
Select a DEMO condition and press
4.
Select "DEMO MODE" and "START" by using
Supplement
During execution of demonstration, [S] is displayed in blinking mode at the bottom of the screen.
To end demonstration, set "DEMO MODE" to "END" or turn off the power.
4.9.15.

Outputting setting value

Setting value can be output to an external unit.
Data is output from a data IN/OUT1 port.
If data IN/OUT1 is set to reception, the port must be set to transmission.
Connect PC to a serial port before output operation.
Procedure
1.
Refer to "4.9.1 Changing to a maintenance mode" to display the maintenance menu.
2.
Set DATA IN/OUT to "SEND" by referencing "4.9.5 Setting a serial port".
3.
Select "INTERFACE" and "DIAGNOSIS" in this order by using
4.
When
is pressed at "CONFIG OUTPUT", data is output to an external unit.
Supplement
When DATA IN/OUT1 is used by setting to transmission, port setting is not required. At
completion of alarm history, the setting is reset to the original output data automatically.
4.9.16.

Setting the current to be displayed

You can set the layer and data No. to be displayed.
The layer that can be displayed is up to three layers from the top.
Normally, set "LAYER" for use.
Procedure
1.
Refer to "4.9.1 Changing to a maintenance mode" to display the maintenance menu.
2.
Press the
3.
Press the
4.
Press the
key to select "CURRENT."
key to select "LAYER," and press the
key to select "DATA No.," and press the
.
.
key.
key.
.
.