Mechanics of Programming

To program the system from a keypad:
• You must use a 2-line Alpha display keypad.
• All partitions must be disarmed.
Data Field Programming Procedures
Task
Entering Program Mode
Go to a Data Field
Entering Data
Review a Data Field
Deleting an Entry
Interactive Mode Programming (∗ ∗ ∗ ∗ 56, ∗ ∗ ∗ ∗ 57, ∗ ∗ ∗ ∗ 58, ∗ ∗ ∗ ∗ 79, ∗ ∗ ∗ ∗ 80, ∗ ∗ ∗ ∗ 81, ∗ ∗ ∗ ∗ 82, ∗ ∗ ∗ ∗ 83)
Entering Interactive Mode
3-8
Procedure
A) Press both [ ∗ ] and [#] at the same time within 50 seconds after
power is applied to the control, OR
B) After power-up, enter [Installer code (4-1-1-2)] + 8 0 0 (long
beep indicates one of the partitions is armed and system cannot
enter program mode).
(method "B" is disabled if you exit the program mode using ∗ 98)
INSTALLER ACCESS NOTE: Some installations may require
that the Installer cannot access the system without the end
user's permission (EN50131-1 compliance). Use field *26, entry
2, to select this option. If selected (Installer code disabled), the
system master or partition master must first enable the Installer
code before it can be used. Once enabled, the Installer code
remains active until any other user enters their code.
To enable the Installer code: master code + [#] + 65
Press [ ∗ ] + [Field Number] (for example, ∗ 21).
A display of "EE" or "Entry Error" means you have entered a
nonexistent field. Simply re-enter [ ∗ ] plus a valid field number.
When the desired field number appears, simply enter the digits
required. The keypad beeps three times after the last digit is
entered and automatically displays the next data field in
sequence.
If entering less than the maximum digits available (e.g., phone
number field), enter the desired digits, then press [ ∗ ] to end the
entry.
Press [#] + [Field Number].
That field's data is displayed, but no changes can be made.
Press [ ∗ ] + [Field No.] + [ ∗ ] (applies only to phone number,
account number, and pager character fields).
Press [ ∗ ] + [Interactive Mode No.] (for example, ∗ 56) while in
Program Mode. The Alpha display keypad will display the first of
a series of prompts requesting entries.
After making the appropriate entry, press the [∗] key to accept
the entry and continue to the next prompt.