PROMPT
ENTER START ZONE
00 = QUIT
36
INPUT S/N
L
AXXX-XXXX
XMIT TO CONFIRM
PRESS
TO SKIP
VALID ENTRIES
Start Zone Number
[∗] to continue
Serial Number
[∗] to continue
Confirm
[∗] to continue
Menu Mode Programming
EXPLANATION
8. The system will search for the highest
available consecutive 4-zone group (the four
zones in the case of the 5804 and 5804BD), and
display the lowest zone number of the group.
If you want to start at a different zone, enter
the zone desired, and press [∗]. If that zone
number is displayed, the system has the
required number of consecutive zones
available, beginning with the zone you
entered. If not, the system will again display a
suggested zone that can be used.
If the required number of consecutive zones is
not available at all, the system will display
"00".
9. Press [∗] to accept.
10. Manually enter the serial number printed on
the label for the wireless key or press and
release the button to transmit its serial
number.
11. Press [∗] to accept the serial number. The
system will check for duplicate.
12. If necessary, press the [#] key to back up
without saving, and re-enter the serial
number.
Use the [A] key to move forward within the
screen, and the [B] key to move backward.
13. If "Yes" was entered at the SET TO
CONFIRM? prompt previously (see first
prompt following entry into the •58 Expert
Programming Mode), the display on the left
will appear. Confirm serial and loop numbers
by activating the wireless key.
IMPORTANT:
When confirmed, the key is not active until it is
assigned to a user number (using the assigning
attributes command, attribute "4"). See System
Operation section for procedure.