Keypad 2 Device Address 17
*190
Entry 1 – Partition Assignment:
0 = keypad disabled
1 = partition 1
Entry 2 – Sound Option:
0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = suppress chime beeps only
3 = suppress arm/disarm, E/E beeps and
chime beeps
Keypad 3 Device Address 18
*191
See field *190 for entries.
Keypad 4 Device Address 19
*192
See field *190 for entries.
Keypad 5 Device Address 20
*193
See field *190 for entries.
Keypad 6 Device Address 21
*194
See field *190 for entries.
Keypad 7 Device Address 22
*195
See field *190 for entries.
Keypad 8 Device Address 23
*196
See field *190 for entries.
EXPLANATION
Keypad 2
Entry 1: enter the partition in which the keypad is
located
2 = partition 2
3 = common
Entry 2: Enter the desired sound option for this
keypad.
NOTE: Address 16 is reserved for keypad 1, which is
factory set to partition 1 with all sounds enabled.
Keypad 3
See field *190 for explanation.
Keypad 4
See field *190 for explanation.
Keypad 5
See field *190 for explanation.
Keypad 6
See field *190 for explanation.
Keypad 7
See field *190 for explanation.
Keypad 8
See field *190 for explanation.