FIELD
TITLE and DATA ENTRIES
Ring Count For Downloading
*95
0 = Disable Monitoring Station initiated
downloading
1–14 = number of rings before control
answers incoming call
#+15 = Answering machine/fax defeat
Data Field Programming
EXPLANATION
Refer to the chart below and program this field
accordingly.
phone
answer/fax down-
module machine
loading
yes
no
no
yes
yes
no
yes
no
yes
yes
yes
yes
no
no
no
no
yes
no
no
no
yes
no
yes
yes
† NOTE:
If "15" is entered to bypass an answering
machine and a TeleCommand Phone Module is
included in the system, you should note the
following:
When calling in from an off-premises phone,
the user should make the initial call, allow 1 or
2 rings only, then hang up, then call again.
The
phone module will now seize the line,
and 2 long tones sound, followed by the usual
voice prompt for the access code. If this
procedure is not followed, phone module
operation will not be possible.
Set field ∗ ∗ ∗ ∗ 95 to...
1-14 (not 0)
higher than number
of rings set on
answer/fax machine
(e.g., if ans/fax
machine is 4 rings,
set this field to 5).
This allows access
via the phone
module if the
answer/fax machine
is turned off.
1-14 (not 0)
15 (bypasses
answer/fax
machine
)
0
0
1-14
15
4-13