FIELD
TITLE and DATA ENTRIES
Zone Bypass Limit
*180
0 = unlimited zone bypasses in each partition
1-7 = number of zone bypasses allowed in
each partition
AC and Clock Display Options
*181
0-15 = desired options based on chart at
right.
Summer Time Switchover Day
*182
0 = switch on Sunday morning
1= switch on Saturday morning
2 = switch on Friday morning
Date/Time Format
*183
0 = 12-hour time/MMDDYY date
1 = 12-hour time/DDMMYY date
2 = 24-hour time/MMDDYY date
3 = 24-hour time/DDMMYY date
Downloader Suppression
*185
Options
0 = no suppression
1 = suppress user code viewing
2 = suppress commands and program
download when armed
3 = suppress user code viewing, commands,
and program download when armed*
Data Field Programming
EXPLANATION
Select the maximum number of zones that can be
bypassed.
Each partition individually uses this entry.
Use the following table to select the desired options for
real-time clock synchronization (50Hz, 60Hz, Crystal),
AC loss display (independent of AC loss report enabled
in *62), and clock display (time displayed on bottom
line of alpha keypads).
X10 NOTE: "X10" (powerline carrier devices) use the
selected AC frequency to communicate with the
control.
Entry
AC Freq.
Crystal for AC Loss disp Clock disp
0
60Hz
clock backup
1
50Hz
clock backup
2
60Hz
clock
3
50Hz
clock
4
60Hz
clock backup
5
50Hz
clock backup
6
60Hz
clock
7
50Hz
clock
8
60Hz
clock backup
9
50Hz
clock backup
#+10
60Hz
clock
#+11
50Hz
clock
#+12
60Hz
clock backup
#+13
50Hz
clock backup
#+14
60Hz
clock
#+15
50Hz
clock
Select the appropriate summer time switchover day.
Select the desired time and date format.
Select the desired options.
*Must be "3" for EN50131-1/prEN50131-3 compliance
no
no
no
no
no
no
no
no
yes
no
yes
no
yes
no
yes
no
no
yes
no
yes
no
yes
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
4-17