Wireless Key Programming Templates - Honeywell ADEMCO Vista-12C Installation And Setup Manual

Table of Contents

Advertisement

Installation and Setup Guide
PROMPT
Zn ZT P RC In
L
10 03 1 10 RF: 1s
Note that an "s"
indicates that a
transmitter's serial
number has been
enrolled.

Wireless Key Programming Templates

This procedure programs the wireless keys, but a key is not active until it is assigned to
a user number (see System Operation section, assigning attributes command).
If the D key was previously pressed (from *58 Menu mode) to enter and duplicate 5804
and/or 5804BD wireless keys, the following screens appear.
PROMPT
TEMPLATE ?
1–6
1
L
01
02
03 04
T
23
22
21 23
PARTITION
1
5-10
VALID ENTRIES
Summary Screen
[∗] to continue
VALID ENTRIES
Template Number
1–3 = 5804 templates
4–6 = 5804BD templates
[∗] to continue
Template Display
[∗] to continue
Partition
1 = partition 1
2 = partition 2
3 = partition 3
[∗] to continue
EXPLANATION
If the serial number transmitted matches the
serial number entered, the keypad will beep 3
times and a summary display will appear,
showing the programmed information for that
zone.
Press [∗] to begin programming the next zone. See
first "Summary Screen" prompt paragraph on
previous page.
EXPLANATION
1. Enter Template number 1–6 (from next page).
See the defaults provided for each template in
the chart that follows these procedures.
2. Select from templates. Press [∗] to display
template (1 shown selected). NOTE: If
necessary, press [#] to back up and re-enter
template number.
3. Press [#] if you want to return to zone
attributes screen.
4. When [∗] is pressed, the selected template will
be displayed.
Top line of display represents loop numbers,
bottom line represents zone type assigned for
each loop.
5. Press [∗] to accept template.
6. Enter the partition in which the key is to be
active.
7. Press [∗] to continue.

Advertisement

Table of Contents
loading