Function Keys; Output Devices; Zone Type Definitions - Honeywell ADEMCO Vista-12C Installation And Setup Manual

Table of Contents

Advertisement

Installation and Setup Guide
2. Enable Pager Delay, if desired, in field *166 (delays alarm reporting for ALL pagers).
3. Enable appropriate user open/close pager reports using the user attribute command
(master code + [8] + user no. + [#] [5] + [1]). Users that perform actions in their assigned
partition will, if enabled, attempt to report to all pagers enabled for open/close reporting
in that partition.
4. If using child-not-home pager report, define the report schedule using Scheduling mode
(master code + [#] [6] [4] then select event type "03").
5. If using a function key to manually send a message to a pager, see Function Keys
paragraph below.
6. If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign
the zones associated with each pager (zone lists 9-11).

Function Keys

To assign functions to the function keys, use *57 Function Key menu mode.
To assign emergency key functions (function key option "00"), first program the respective
emergency zone number (95 for "A" key, 96 for "C" key, 99 for "B" key) with the desired zone
type using *56 Zone Programming mode, then use *57 Function Key menu mode to assign
the desired key.
If using a function key to activate a relay action (*57 Menu mode key function 07), use *79
Menu mode to map the output, and use *80 Menu mode to define the output's action; select
system operation type "66."
If using a function key for a user macro, use *57 menu mode to activate the desired key, then
define the actual macro functions using the user code + [#] + [6] [6] command.

Output Devices

To program a device for manual activation (user code + [#] [7] / [#] [8] + 2-digit device
number) or for scheduled automatic activation, simply map the device using *79 Menu mode.
To program a device to automatically activate upon a system event (or function key), use *79
Menu mode to map the device, then use *80 Menu mode to define the automated device
action.
If the device action is based on more than one zone, use *81 Zone List menu mode to assign
the zones.

Zone Type Definitions

You must assign a zone type to each zone, which defines the way in which the system
responds to faults in that zone. Zone types are defined below.
Zone Type
Type 00: Zone Not Used
3-4
Description
Program a zone with this zone type if the zone is not used.