Device Programming - Honeywell Lynx Plus Programming Manual

Hide thumbs Also See for Lynx Plus:
Table of Contents

Advertisement

Use this mode to program Powerline Carrier Devices or zone lists for Chime by Zone feature. It is also used to
program the Remote Services Multi-mode (e-mail) event triggers. Press
Note: Entering a number other than the one specified may give unpredictable results.
80 80 80 80
DEVICE PROG
DEVICE
DEVICE
DEVICE
PROG
PROG
PROG MENU
MENU
MENU
MENU
A01
A01
A01
A01
DEVICE
DEVICE NUMBER
NUMBER
DEVICE
DEVICE
NUMBER
NUMBER
b
DEVICE
DEVICE ACTION
DEVICE
DEVICE
ACTION
ACTION
ACTION
C C C C
START
START
START EVENT
START
EVENT
EVENT
EVENT TYPE
TYPE
TYPE
TYPE
d
START
START
START
START ZONE
ZONE
ZONE LIST
ZONE
LIST
LIST
LIST
E E E E
START ZONE
START
ZONE TYPE
TYPE
START
START
ZONE
ZONE
TYPE
TYPE
F F F F
STOP ZONE
STOP
STOP
STOP
ZONE
ZONE
ZONE LIST
LIST
LIST
LIST
1A 1A 1A 1A
STOP
STOP ZONE
STOP
STOP
ZONE
ZONE TYPE
ZONE
TYPE
TYPE
TYPE
Powerline Carrier Device Programming
0 = Exit mode, upon which this prompt blinks.
1 = Enter mode
Device Number
Enter the 2-digit device number to be programmed
01-08 = X10 device number
09-16 = Multimode (e-mail) event triggers
[✻] = Continue
00 = Exit Device Programming mode (displays blinking 80; enter ✻ + desired data field or
menu mode number)
Device Action
Enter the 1-digit action, 0-3, for the device being programmed (current action is displayed).
0 = No response
1 = Close for 2 seconds
2 = Close and stay closed
Start Event Type (If applicable)
Enter the 1-digit start event type, 0-3, for the device being programmed.
0 = Not used
1 = Alarm
2 = Fault
Start Zone List (If applicable)
Enter the 1-digit zone list number, 1-3, or 0 if not used, for the device being programmed.
[
] = Continue
[#] = Return to previous prompt
Start Zone Type (If applicable)
Enter the 2-digit start zone type for the device being programmed (see Powerline Carrier
Device Worksheet for zone type/system operation codes later in this manual).
[
] = Continue
[#] = Return to previous prompt
Stop Zone List (If applicable)
Enter the 1-digit zone list number, 1-3, or 0 if not used, for the device being programmed.
[
] = Continue
[#] = Return to previous prompt
Stop Zone Type (If applicable)
Enter the 2-digit stop zone type for the device being programmed (see Powerline Carrier
Device Worksheet for zone type/system operation codes later in this manual).
[
] = Continue to Device Number prompt (A)
[#] = Return to previous prompt
✻ ✻ ✻ ✻ 80 DEVICE PROGRAMMING
80 while in programming mode.
3 = Pulse on and off
[✻] = Continue
[#] = Return to previous prompt
3 = Trouble
[
] = Continue
[#] = Return to previous prompt
- 15 -