Honeywell Lynx Plus Programming Manual page 11

Hide thumbs Also See for Lynx Plus:
Table of Contents

Advertisement

F F F F
DELETE
DELETE ZONE
DELETE
DELETE
ZONE
ZONE
ZONE
1 1 1 1 A A A A
ENROLL MODE
ENROLL
ENROLL
ENROLL
MODE
MODE
MODE
1 1 1 1 b
SERIAL
SERIAL
SERIAL
SERIAL NUMBER
NUMBER
NUMBER
NUMBER
1 1 1 1 C C C C
ZON
ZON
ZONE E E E DESCRIPTOR
ZON
DESCRIPTOR
DESCRIPTOR
DESCRIPTOR
1 1 1 1 d
Note: System displays 2-digit
selection & alpha
descriptor OR 99 "No
selection"
✻ ✻ ✻ ✻ 56 ENHANCED ZONE PROGRAMMING PROCEDURE
Loop Number or Loop & Serial Number (if using RF Learning) (Continued)
Manual Entry - Enter the desired loop number and press [✻] to continue (see the
transmitter's Installation Instructions for specific loop designations). If "LEARNED" is
displayed, the zone's serial number has already been enrolled.
Note: The loop number can be changed even if the zone has already been entered. Care
should be taken when using this feature. It is possible to make zones inoperable by
creating a mismatch of a working serial number/loop number combination. This
should be re-confirmed if the loop number is changed.
1-4 = Loop number for the zone of the transmitter being entered or learned
0 + [
] = Delete Serial Number prompt (F)
[
] = Continue to the ENROLL MODE prompt (1A) if not enrolled, or VOICE DESCRIPTOR
prompt (1C) if already enrolled.
[#] = Return to previous prompt
Delete Zone Parameters
If 00 was entered in the Zone Type field or if 0 was entered in the Loop Number field,
confirmation of the delete request will delete all information associated with zone currently
being programmed.
Note: 00 was entered as a zone type in prompt (b), 00 will be retained and system will
advance to prompt (1C).
0 = Discard the delete request.
1 = Confirm the requested delete.
Enroll Mode
Confirm, delete or enter Serial Number
0 = Skip to the VOICE DESCRIPTOR prompt (1C). If zone type is "00", then skips to
DELETE SERIAL NUMBER prompt instead.
1 = Enroll now and proceed to SERIAL NUMBER prompt (1b) (If "LEARNED" is not
displayed).
2 = Copy the last serial number from the local memory buffer (If "LEARNED" is not
displayed).
9 = Delete existing serial number. (Only if "LEARNED" is displayed).
[
] = Advance to the VOICE DESCRIPTOR prompt (1C). This will save all zone
parameters.
[#] = Return to the loop number prompt (E).
Serial Number
Manually enter the 7-digit serial number printed on the transmitter. If an incorrect digit is
entered, press the [#] key to return to prompt (1A). When all 7 digits are entered, press
the [✻] key. The serial number will be copied into EEROM and the local memory buffer and
the system will return to the (1A) prompt and "LEARNED" will be displayed. If 52 seconds
pass and no entry is been made, the system will return to prompt (1A).
Note: In order for all parameters to be accepted, you must advance to prompt (1C).
Voice Descriptor
0 = Skip to next zone (A)
1 = Enter descriptor mode (existing zone descriptor will be announced, then descriptor 1
will be repeated)
Descriptor 1
Enter [#] + 2-digit vocabulary index† number of first descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 = accept word and advance to descriptor 2 (descriptor 2 will be announced)
8 = accept word and advance to next zone (prompt A) – zone descriptor will be
announced
Press any other key to repeat the selected word
- 11 -

Hide quick links:

Advertisement

Table of Contents
loading