Piping And Drain Hose Installation; Die-Cutting Front Panel Slit; Changing Drain Hose; How To Install And Remove The Drain Hose - Toshiba RAS-B10N3KV2-E Service Manual

Split type air conditioner
Hide thumbs Also See for RAS-B10N3KV2-E:
Table of Contents

Advertisement

Control wire
Hole for hang
remote controller
Remote controller
Remote controller
"
Screw
Tighten fi rmly but
not over 0.15 N·m
(0.02 kgf·m)
Fig. 10-3-10
*Remark :
1. Recommend to use double insulation lead wire for
connect remote control and air conditioner.
2. For wire operation, 1 remote control can control only
1 indoor unit.
3. In wire operation, remote controller will return to initial
condition (PRESET, TIMER and CLOCK will return to
initial condition) when user shutdown power supply
of air conditioner.
<How to install the air inlet grille on the indoor unit>
• When attaching the air inlet grille, the contrary of the
removed operation is performed.

10-3-4. Piping and drain hose installation

<Piping and drain hose forming>
* Since dewing results in a machine trouble, make
sure to insulate both the connecting pipes. (Use
polyethylene foam as insulating material.)
Control wire
Screw (∅3.1 x 16L) for
hang remote controller
Wall
Screw (∅3.1 x 25L) for
fi x battery cover
#
Battery cover
$
Rear right
Rear left
Bottom left
Left
Bottom right
Right

1. Die-cutting front panel slit

Cut out the slit on the left or right side of the front
panal for the left or right connection and the slit on th
bonttom left or right side of the front panel for the botto
left or right connection with a pair of nippers.

2. Changing drain hose

For leftward connection, bottom leftward connection
and rear leftward connection's piping, it is necessary to
change the drain hose and drain cap.
How to remove the drains cap
Clip drain cap by needle-nose plier, and pull out.
How to install the drain hose
Firmly insert drain hose connecting part until hitting on
a heat insulator and fix it with a screw.
How to remove the drain hose
The drain hose can be removed by
take off screw, after that twisting and
pulling.
When removing the drain hose, be
careful of any sharp edges of steel
plate. The edges can cause injuries.
To install the drain hose, insert the drain hose firmly
until the connection part contacts with heat insulator,
and the secure it with original screw.
Heat insulator
Drain hose
55
FILE NO. SVM-12050
Fig. 10-3-11
Fig. 10-3-12
CAU

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10n3av2-eRas-b13n3kv2-eRas-13n3av2-e

Table of Contents