Quiet Mode; Comfort Sleep Mode; One-Touch Comfort - Toshiba RAS-B10N3KV2-E Service Manual

Split type air conditioner
Hide thumbs Also See for RAS-B10N3KV2-E:
Table of Contents

Advertisement

Item

15. QUIET mode

When the [QUIET] button is pressed, the fan of the
indoor unit will be restricted the revolving speed at
speed L
again (cancel Quiet mode).
16. COMFORT
Cooling mode
SLEEP mode
• The preset temperature will increase as
show on ECO operation (Item No. 9)
• Press the [COMFORT SLEEP] button to
choose the operating hours. Repeat
pressing to select the hours.
(1hr, 3hr, 5hr or 9hr)
• If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
Heating mode
• The preset temperature will drop down as
show on ECO operation (Item No. 9)
• Press the [COMFORT SLEEP] button to
choose the operating hours. Repeat
pressing to setect thehours.
(1hr, 3hr, 5hr or 9 hr)
• If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
17. One-Touch
One touch comfort is the fully automated operation
Comfort
that is set according to the preferable condition in
a region.
Fan
Operation
*AUTO/L: Fan operates depends on the setting
temperature and room temperature.
During the One Touch Comfort mode if the indoor
unit receives any signal with other operation mode,
the unit will cancel the comfort mode and operates
according to the signal received.
Operation flow and applicable data, etc.
until the [QUIET] button is pressed once
AUTO
* AUTO/L
0
12
25
Quiet mode is the system which, control the
revolving speed of indoor fan to work
constantly at lower than speed L. In addition,
noise level of indoor unit is less than usual.
Remarks :
1. Quiet mode is unable to work in dry mode.
2. Quiet mode is appropriate to work with less
cooling load and less heating load condition.
Because of the fan speed L- may cause not
enough the cooling capacity or heating
capacity.
The principles of comfort sleep mode are:
• Quietness for more comfortable. When
room temperature reach setting temperature
• Save energy by changing room temperature
automatically.
• The air condition can shut down by itself
automatically.
Remarks:
1. Comfort sleep mode will not operate in dry
mode and fan only mode.
Operation condition for model to Europe
market
When an indoor unit receives "One Touch
Comfort Signal" from the remote controller,
the indoor unit operates as following.
1) Air conditioner starts to operation when
L
2) Operation mode is set according to room
3) Target temperature is 24ºC.
Time after operation
4) Louver position is set as stored position
starts (min)
5) Fan is controlled as followings.
− 40 −
FILE NO. SVM-12050
Description
the signal is received, even if the air
conditioner was OFF.
temperature, the same as AUTO mode.
of the operating mode.
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10n3av2-eRas-b13n3kv2-eRas-13n3av2-e

Table of Contents