Piping And Drain Hose Installation - Toshiba RAS-B16J2AVSG-E Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

1
Screw
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
Notch for wire out
Control wire
3
For remote controller
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the plastic for
cover hole as shown on fi gure 4.
4. Insert control wire from rear side of remote controller as shown on
fi gure 5.
5. Fix control wire which arrange as shown on fi gure 6 and 7 to terminal
by provided screws (tighten fi rmly but not over 0.25 N·m (0.03 kgf·m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on fi gure 8.
7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as
shown on fi gure 9.
8. Mark and arrange hole for fi x below screw (Ø3.1×25L) as shown on
fi gure 9.
9. Assembly battery cover which provided with accessory bag then use
provide screw (Ø3.1×25L) to fi x battery cover together with wall as
shown on fi gure ! (tighten fi rmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
4
1.5V
1.5V
Plastic for cover hole
7
Control wire
Terminal
Front panel
Screw
Screw cap
2
70 mm
5 mm
Control wire
Terminal
5
6
30 mm
5 mm
20 mm
* Wire size 28-22AWG
Control wire
or 0.08-0.32 mm
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
1.5V
1.5V
Display
unit
*Remark : 1. Recommend to use double insulation lead wire for connect
2. For wire operation, 1 remote control can control only 1 indoor
3. In wire operation, remote controller will return to initial

Piping and Drain Hose Installation

Piping and drain hose forming
* Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right
1. Die-cutting back body slit
Cut out the slit on the left or right side of the back body for the left or right
connection and the slit on the bottom left or right side of the back body
for the bottom left or right connection with a pair of nippers.
2. Changing drain hose
For leftward connection, bottom-leftward connection and rearleftward
connection's piping, it is necessary to change the drain hose and drain
2
cap.
8
Hole for hang
remote controller
Control wire
Remote controller
Remote controller
8
Battery cover
Screw
Tighten fi rmly but not over
0.15 N·m (0.02 kgf·m)
remote control and air conditioner.
unit.
condition (PRESET, TIMER and CLOCK will return to
initial condition) when user shutdown power supply of air
conditioner.
Control wire
Screw (Ø3.1×16L)
for hang remote
controller
Wall
Screw (Ø3.1×25L)
for fi x battery cover
9
!

Advertisement

Chapters

Table of Contents
loading

Table of Contents